Connections and Wiring
I/O Port Wiring Specifications
NI-4000 and NI-3000
Pin
1
2
3
4
5
6
7
8
9
10
IR/Serial Connections and Wiring
You can connect up to eight IR- or Serial-controllable devices to the IR/Serial connectors on the
rear of the NI-4000 and NI-3000 and up to four on the NI-2000 (FIG. 16). These connectors accept
an IR emitter (CC-NIRC) that mounts onto the device's IR window, or a mini-plug (CC-NSER) that
connects to the device's control jack. You can also connect a data 0 - 5 VDC device. These units
come with two CC-NIRC IR emitters (FG10-000-11).
8
7
NI-4000/NI-3000 IR/Serial connector
FIG. 16 IR/SERIAL (male)
The IR/Serial connector wiring specifications are listed in the following table.
IR/Serial Connector Wiring Specifications
No.
1
2
3
4
5
6
7
8
26
Signal
Function
GND
Signal GND
I/O 1
Input/Output
I/O 2
Input/Output
I/O 3
Input/Output
I/O 4
Input/Output
I/O 5
Input/Output
I/O 6
Input/Output
I/O 7
Input/Output
I/O 8
Input/Output
12 VDC
PWR
IR / SERIAL (Ports 9-16)
6
5
4
3
2
1
configuration (Port 9-16)
NI-4000/3000 Port
NI-2000 Port
9
10
11
12
13
N/A
14
N/A
15
N/A
16
N/A
I/O Port Wiring Specifications NI-2000
Pin
Signal
1
2
3
4
5
12 VDC
IR / SERIAL (Ports 5-8)
4
3
2
1
NI-2000 IR/Serial connector
configuration (Port 5-8)
Signal
5
6
7
8
Function
GND
Signal GND
I/O 1
Input/Output
I/O 2
Input/Output
I/O 3
Input/Output
PWR
Function
GND (-)
Signal 1 (+)
GND (-)
Signal 2 (+)
GND (-)
Signal 3 (+)
GND (-)
Signal 4 (+)
GND (-)
Signal 5 (+)
GND (-)
Signal 6 (+)
GND (-)
Signal 7 (+)
GND (-)
Signal 8 (+)
NetLinx Integrated Controllers