Shutdown Diagnostics

The unit has the ability to report the cause of the last shutdown of the remote engine starting
system. To enter diagnostic mode:
1. Turn the ignition off.
2. Press and HOLD the Valet/Program switch.
3. Turn the ignition on and then off.
4. Release the Valet/Program switch.
5. Press and release the Valet/Program switch. The LED status indicator will now
report the last system shutdown by flashing for one minute in the following
grouped patterns (see following table). The LED status indicator will stop
flashing when the ignition is turned on.
LED Flashes
One
Two
Three
Four
Six
Seven
Eight

Long Term Event History

The system stores the last two full triggers in memory. These are not erasable. Each time the unit
sees a full trigger, the older of the two triggers in memory will be replaced by the new trigger. To
access long term event history:
www.clifford.com
Shutdown Mode
Timed out
Over-rev shutdown
Low or no RPM
Transmitter shutdown (or optional push-button)
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Wait-to-start timed out
41