Auxiliary Circuit Breaker; Electrical Work - Samsung AS12A1VC Owner's Instructions & Installation Manual

Ductless mini-split
Table of Contents

Advertisement

AS12A1VC-E
1/26/00 3:16 PM

Auxiliary Circuit Breaker

Auxiliary circuit breaker should be installed near outdoor unit so that each
access is possible.
Main/outdoor power supply cable are connected to upper/lower terminal of
auxiliary circuit breaker.
It is necessary that the conduit kit for power supply to the outdoor unit be
installed between auxiliary power S/W and the outdoor unit.
(the conduit kit is optional)

Electrical Work

1 The supply voltage must be the same as the rated voltage of the air conditioner.
2 Prepare the power souce for exclusive use with the air conditioner.
3 Use 15 amperes time delay fuse or circuit breaker.
Model
Power supply
Power cable
Assembly cable
Operating current
Starting Current
Power consumption
When using the special NFB, use the NFB to bear the capacity of the
air conditioner.
Otherwise, the shot circuit in the NFB may be occur.
Page 13
AS12
VC
208-230V~/60Hz Single phase
115V~/60Hz Single phase
3G AWG14
4G AWG14 + 1G AWG18
6A
33A
1280W
Outdoor
unit
AS09
VA
AS07
115V~/60Hz Single phase
3
3
8
A
6
10
10
45A
34A
880W
670W
I
O
NSTALLING THE
UTDOOR
Distribution
board
Auxiliary
power
s/w
conduit kit
N
L
1
2
3
N
L
E
VA
A
U
NIT
35
E-