Mitsubishi Electric FR-A701 Instrucion Manual page 119

Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

Parameter List
Parameter
Motor excitation
82
current
Rated motor
83
voltage
84
Rated motor frequency
Motor constant (R1)
90
Motor constant (R2)
91
Motor constant (L1)
92
Motor constant (L2)
93
Motor constant (X)
94
Auto tuning setting/
96
status
Second motor
455
excitation current
Rated second
456
motor voltage
Rated second
457
motor frequency
112
Incre
Initial
Name
ments
Value
0.01A
9999
200/
0.1V
400V *
0.01Hz
60Hz
0.001Ω
9999
0.001Ω
9999
0.001Ω
9999
(0.1mH)
0.001Ω
9999
(0.1mH)
0.01Ω
9999
(0.1%)
1
0
0.01A
9999
200/
0.1V
400V *
0.01Hz
60Hz
Range
Description
Tuning data
0 to 500A
(The value measured by offline auto tuning
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Set the rated motor voltage(V).
* The initial values differ according to the
0 to 1000V
voltage level. (200V/400V)
10 to 120Hz Set the rated motor frequency (Hz).
Tuning data
0 to 50Ω
(The value measured by offline auto tuning
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Tuning data
0 to 50Ω
(The value measured by offline auto tuning
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Tuning data
0 to 50Ω (0
(The value measured by offline auto tuning
to 1000mH)
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Tuning data
0 to 50Ω (0
(The value measured by offline auto tuning
to 1000mH)
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Tuning data
0 to 500Ω
(The value measured by offline auto tuning
(0 to 100%)
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
0
Auto tuning is not performed
1
Tuning performed without motor running
101
Tuning performed with motor running
Tuning data of the second motor
0 to 500A
(The value measured by offline auto tuning
is automatically set.)
Use the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series)) constants
Set the rated voltage (V) of the second
motor.
0 to 1000V
* The initial values differ according to the
voltage level. (200V/400V)
Set the rated frequency (Hz) of the second
10 to 120Hz
motor.
All
Para
Param
param
meter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading