Carrier 50HS Product Data page 8

Single-package heat pumps 1/2 to 5 nominal tons
Hide thumbs Also See for 50HS:
Table of Contents

Advertisement

Dimensions (cont)
ELECTRICAL
UNIT
CHARACTERISTICS
50HS042,048 208/230-1-60, 208/230-3-60, 460-3-60 379 172 94/43 86/39 118/54 81/37
50HS060
208/230-1-60, 208/230-3-60, 460-3-60 393 179 97/44 90/41 121/55 85/39
REQ'D CLEARANCES FOR SERVICING — in. (mm)
Indoor Coil Access Side . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 (762)
Control Box Access Side (Except for NEC requirements) . . . . . . . . . . 30 (762)
Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 (914)
Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 (762)
REQ'D CLEARANCES TO COMBUSTIBLE MAT'L — in. (mm)
Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Duct Side of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Bottom of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Vertical Discharge, First 12 in. (305) of Supply Duct
8
SIZES 042-060 WITH OPTIONAL BASE RAIL
UNIT WT
CORNER WT (Lb/Kg)
Lb
Kg
A
B
. . . . . . . . . . . . . 1 (25)
UNIT
C
D
50HS042,048
50HS060
NEC REQ'D CLEARANCES — in. (mm)
Between Units, Control Box Side . . . . . . . . . . . . . 42 (1067)
Unit and Ungrounded Surfaces, Control Box Side . . . . . .36 (914)
Unit and Block or Concrete Walls and Other
Grounded Surfaces, Control Box Side . . . . . . . . . . 42 (1067)
LEGEND
CG
— Center of Gravity
MAT'L — Material
NEC
— National Electrical Code
REQ'D — Required
NOTES:
1. Clearances must be maintained to prevent recirculation of air from
outdoor-fan discharge.
2. Dimensions in ( ) are in mm.
CENTER OF GRAVITY (in./mm)
X
Y
Z
19.6/498
20.6/524
17.3/440
19.6/497
20.6/524
17.3/440