50HS024 (2 TONS)
Temp (F)
Indoor
Air Ent
Air
Indoor
Cfm
–10
Coil
(std)
Cap. 3.85 3.85 7.20 7.20 10.60
700
kW
1.73
Cap. 3.97 3.97 7.39 7.39 10.80 10.20 13.20 12.00 14.20 12.80 17.60 15.50 21.90 21.00 24.80 24.80 26.00 26.00 29.80 29.80
60
800
kW
1.77
Cap. 4.04 4.04 7.52 7.52 11.00 10.40 13.40 12.20 14.50 13.10 18.00 15.70 22.30 21.30 25.30 25.30 26.40 26.40 30.20 30.20
900
kW
1.82
Cap. 3.47 3.47 6.67 6.67
700
kW
1.75
Cap. 3.59 3.59 6.85 6.85 10.10
70
800
kW
1.79
Cap. 3.54 3.65 6.97 6.97 10.30
900
kW
1.84
Cap. 2.85 2.85 5.98 5.98
700
kW
1.76
Cap. 2.95 2.95 6.14 6.14
80
800
kW
1.80
Cap. 3.06 3.06 6.29 6.29
900
kW
1.85
50HS030 (2
⁄
TONS)
1
2
Temp (F)
Indoor
Air Ent
Air
Indoor
Cfm
−10
Coil
(std)
Cap. 4.25 4.25 8.41 8.41 12.60 11.90 15.50 14.10 16.70 15.10 20.90 18.30 26.30 25.30 30.10 30.10 32.00 32.00 38.20 38.20
875
kW
1.99
Cap. 4.30 4.30 8.55 8.55 12.80 12.10 15.80 14.40 17.00 15.40 21.30 18.70 26.90 25.80 30.80 30.80 32.60 32.60 38.80 38.80
60
1000
kW
2.03
Cap. 4.37 4.37 8.69 8.69 13.00 12.30 16.00 14.60 17.30 15.60 21.60 19.00 27.30 27.30 26.20 31.30 33.10 33.10 39.30 39.30
1125
kW
2.08
Cap. 3.92 3.92 7.91 7.91 11.90 11.20 14.70 13.40 15.90 14.30 19.90 17.40 25.10 24.10 28.80 28.80 30.60 30.60 36.60 36.60
875
kW
2.04
Cap. 3.99 3.99 8.07 8.07 12.10 11.50 15.00 13.70 16.20 14.60 20.30 17.80 25.70 24.60 29.40 29.40 31.20 31.20 37.30 37.30
70
1000
kW
2.09
Cap. 4.10 4.10 8.23 8.23 12.40 11.70 15.30 13.90 16.50 14.90 20.60 18.10 26.10 25.10 30.00 30.00 31.80 31.80 37.90 37.90
1125
kW
2.13
Cap. 3.25 3.25 7.14 7.14 11.00 10.40 13.80 12.50 14.90 13.40 18.80 16.50 23.80 22.80 27.30 27.30 29.00 29.00 34.90 34.90
875
kW
2.08
Cap. 3.44 3.44 7.39 7.39 11.30 10.70 14.10 12.80 15.30 13.80 19.20 16.80 24.30 23.40 27.90 27.90 29.70 29.70 35.80 35.80
80
1000
kW
2.13
Cap. 3.56 3.56 7.56 7.56 11.60 10.90 14.40 13.10 15.60 14.00 19.60 17.20 24.80 23.80 28.50 28.50 30.30 30.30 36.50 36.50
1125
kW
2.17
Cap. — Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)
db
— Dry Bulb
kW
— Total Power Input (Includes Compressor Motor Power Input, Outdoor-
Fan Motor Input, and Indoor-Fan Motor Input)
rh
— Relative Humidity
HEATING CAPACITIES (cont)
Air Temp Entering Outdoor Coil (F db at 70% rh)
0
10
9.96
12.90 11.80 13.90 12.50 17.30 15.10 21.40 20.50 24.30 24.30 25.50 25.50 29.70 29.70
1.81
1.89
1.95
1.85
1.92
1.97
1.88
1.95
2.00
9.88
9.32
12.10 11.10 13.10 11.80 16.30 14.30 20.30 19.40 23.10 23.10 24.30 24.40 28.60 28.60
1.84
1.93
1.99
9.54
12.40 11.30 13.40 12.10 16.60 14.60 20.70 19.90 23.60 23.60 24.80 24.80 29.00 29.00
1.88
1.96
2.02
9.72
12.60 11.50 13.60 12.30 17.00 14.90 21.10 20.30 24.00 24.00 25.30 25.30 29.30 29.30
1.92
1.99
2.05
9.10
8.59
11.30 10.30 12.20 11.00 15.40 13.50 19.10 18.40 21.80 21.80 23.10 23.10 27.20 27.20
1.86
1.96
2.03
9.33
8.80
11.60 10.50 12.50 11.30 15.70 13.80 19.60 18.80 22.30 22.30 23.60 23.60 27.80 27.80
1.90
2.00
2.06
9.53
8.99
11.80 10.70 12.80 11.50 16.00 14.00 20.00 19.20 22.80 22.80 24.00 24.00 28.20 28.20
1.94
2.03
2.09
Air Temp Entering Outdoor Coil (F db at 70% rh)
0
10
2.11
2.24
2.33
2.15
2.27
2.35
2.19
2.30
2.38
2.18
2.32
2.41
2.22
2.35
2.44
2.26
2.38
2.47
2.23
2.38
2.49
2.27
2.41
2.52
2.31
2.45
2.55
LEGEND
17
20
30
1.97
2.05
2.00
2.07
2.02
2.09
2.02
2.11
2.05
2.13
2.07
2.15
2.06
2.17
2.09
2.19
2.12
2.21
17
20
30
2.37
2.49
2.39
2.50
2.41
2.52
2.46
2.59
2.48
2.61
2.51
2.63
2.53
2.68
2.56
2.70
2.59
2.73
NOTES:
1.
indicates integrated ratings.
2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost
on the outdoor coil and the heat required to defrost it.
40
47
50
2.15
2.22
2.24
2.16
2.22
2.23
2.17
2.23
2.24
2.22
2.29
2.32
2.23
2.30
2.32
2.25
2.31
2.33
2.28
2.36
2.39
2.30
2.37
2.40
2.31
2.38
2.41
40
47
50
2.64
2.75
2.79
2.64
2.74
2.78
2.65
2.74
2.78
2.76
2.87
2.92
2.76
2.87
2.92
2.78
2.88
2.92
2.86
2.98
3.03
2.87
2.98
3.03
2.88
2.99
3.04
60
2.31
2.28
2.27
2.41
2.39
2.38
2.50
2.49
2.48
60
2.95
2.91
2.90
3.09
3.07
3.06
3.22
3.21
3.20
13