Panel Assy/ Cover Open Sensor - Epson L800 Service Manual

Color inkjet printer
Hide thumbs Also See for L800:
Table of Contents

Advertisement

L800/L801

1.4.2 Panel Assy/ Cover Open Sensor

Removal procedure
Panel Assy removal
1.
Disconnect the Panel FFC from the connector (CN5) on the Main Board and
peel the Panel FFC off the Cable Holder Frame.
2.
Disconnect the CDR Sensor Cable and Cover Open Sensor Cable from the
connectors (CN4, CN17) on the Main Board.
3.
Release the CDR Sensor Cable and Cover Open Sensor Cable from the two
hooks of the Cable Holder Frame.
4.
Peel off the acetate tape A, B to separate the CDR Sensor Cable from the
Cover Open Sensor Cable.
CN17
CN4
Cover Open Sensor and
CDR Sensor Cable
CN5
Main Board
Figure 1-29. Removing the Panel Assy (1)
Disassembly/Reassembly
Hooks and Acetate Tape A, B
Cable Holder
Panel FFC
Frame
Double sided Tape
Panel Assy/ Cover Open Sensor
When removing the screw (2) shown in Fig.1-30, be careful not to
C A U T I O N
damage the Cover Open Sensor Cable and CDR Sensor Cable.
5.
Remove the two screws.
Screw
(3 pcs.): C.B.P. M3x6 (tightening torque: 5-7 kgf.cm)
Screw
(3 pcs.): C.B.P. M3x10 (tightening torque: 5-7 kgf.cm)
6.
From the bottom of the Printer, insert a flathead screwdriver into the hole to
disengage the tab, and remove the Panel Assy.
Panel Assy
2
1
Figure 1-30. Removing the Panel Assy (2)
Revision A
Open Sensor Holder
[Front side]
Tab
Disengage
direction
Housing Lower
30
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L801

Table of Contents