Setting the light flash polarity

Light flash (+) / (-) polarity
The internal fuse is used to determine the light flash output. In the (+) position,
the onboard relay will output (+)12V on the WHITE wire, H1/11. In the (-) posi-
tion, the on-board relay will supply a (-) output When wiring into a multiplex
circuit, you can replace the fuse with a resistor (paying attention to the polarity
setting). (Refer to diagram on p.25, H1/4 White/ Brown wire description).
Note: For parking light circuits that draw 10 amps or more, the internal jumper
must be switched to a (-) light flash output. P/N 8617 or a standard automotive
SPDT relay must be used on the H1/11 light flash output harness wire.
© 2008 Directed Electronics—all rights reserved
(Light Flash Fuse Jumper is under
access door - use needle nose pliers to
change fuse position)