Carrier 30GTN Service And Troubleshooting Manual page 2

Air-cooled reciprocating with comfortlink controls 50/60 hz controls, start-up, operation, service, and troubleshooting
Table of Contents

Advertisement

CONTENTS (cont)
Head Pressure Control . . . . . . . . . . . . . . . . . . . . . . 27
Pumpout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Marquee Display Usage . . . . . . . . . . . . . . . . . . . . . 29
Service Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Temperature Reset . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Demand Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
(4 to 20 mA Controlled)
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . 46-51
(CPCS) Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
330A/B-420A/B) . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
EXV Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . 46
Alarms and Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52-64
Electronic Components . . . . . . . . . . . . . . . . . . . . . 52
Compressors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Condenser Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Condenser Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Refrigerant Feed Components . . . . . . . . . . . . . . . 56
Thermistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Safety Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Relief Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Other Safeties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
PRE-START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
System Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
START-UP AND OPERATION . . . . . . . . . . . . . . . 65,66
Actual Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Operating Limitations . . . . . . . . . . . . . . . . . . . . . . . 65
Page
Operation Sequence . . . . . . . . . . . . . . . . . . . . . . . . 66
APPENDIX A - CCN TABLES . . . . . . . . . . . . . . 67-74
START-UP CHECKLIST . . . . . . . . . . . . . . CL-1 to CL-8
Unit sizes 230-420 are modular units which are shipped
as separate sections (modules A and B). Installation instruc-
tions specific to these units are shipped inside the individual
modules. See Table 1 for a listing of unit sizes and modular
combinations. For modules 230B-315B, follow all general
instructions as noted for unit sizes 080-110. For all remain-
ing modules, follow instructions for unit sizes 130-210.
This publication contains Start-Up, Service, Controls, Op-
eration, and Troubleshooting information for the 30GTN,R040-
420 liquid chillers with ComfortLink controls.
The 30GTN,R chillers are equipped with electronic ex-
pansion valves (EXVs) or, on size 040-110 FIOP (factory-
installed option) units, conventional thermostatic expansion
valves (TXVs). The size 040-110 FIOP chillers are also
equipped with liquid line solenoid valves (LLSV).
NOTE: TXVs are not available on modular units.
Differences in operations and controls between standard
and 040-110 FIOP units are noted in appropriate sections in
this publication. Refer to the Installation Instructions and the
Wiring Diagrams for the appropriate unit for further details.
This unit uses a microprocessor-based electronic con-
trol system. Do not use jumpers or other tools to short
out or bypass components or otherwise depart from
recommended procedures. Any short-to-ground of the
control board or accompanying wiring may destroy the
board or electrical component.
Table 1 - Unit Sizes and Modular Combinations
UNIT MODEL
30GTN,R
40
45
50
60
70
80
90
100
110
130
150
170
190
210
230
245
255
270
290
315
330
360
390
420
*60 Hz units/50 Hz units.
2
GENERAL
INTRODUCTION
NOMINAL
SECTION A
TONS
UNIT 30GTN,R
40
-
45
-
50
-
60
-
70
-
80
-
90
-
100
-
110
-
125
-
145
-
160
-
180
-
200
-
220
150
230
150
240
150
260
170
280
190
300
210
325
170
350
190
380
210
400
210
Page
SECTION B
UNIT 30GTN,R
-
-
-
-
-
-
-
-
-
-
-
-
-
-
080
090
100
100
110
110
170
190/170*
190
210

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents