Floor Protection; Vent Requirements - Lopi Spirit Owner's Manual

Gas stove room heater
Hide thumbs Also See for Spirit:
Table of Contents

Advertisement

S
TOVE

Floor Protection

When the stove is installed directly on carpeting, vinyl or other combustible material other than
wood flooring, the stove must be installed on a metal or wood protection panel extending the full
width and depth of the stove.

Vent Requirements

The vent must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1
and the requirements listed below. Furthermore, the vent must be installed to meet the
installation requirements of the vent manufacturer.
¥
¥
¥
¥
¥
¥
¥
Min. 5' Rise
Standard Installation
I
NSTALLATION
Minimum 5' vertical rise from top of stove (see the illustration below)
The horizontal run may not exceed 50% of the vertical rise
Use 4" dia. B vent for entire system from one manufacturer (don't mix brands)
Use high temperature factory built chimney and connector with listed gas
chimney liner running the entire length
The vent must not service another appliance
1" clearance to all combustibles must be maintained
Must meet all of the vent manufacturer's requirements
Vent termination must be above the roof and not below any eaves or overhangs
Vent must
terminate a
minimum 1'
above the roof.
Maintain 1"
minimum
clearance
Provide a 1/4" rise
for every 12" run.
Type B Vent
Exterior Vent
(C
.) -
ONT
For qualified installers only!
- or -
Min. 5' Rise
The total
horizontal
run must
not exceed
50% of the
vertical rise
Do not block gas
vent termination
High
temperature
factory built
chimney and
connector
Listed Gas
Chimney Liner
Chimney with Liner
P
7
AGE