Specifications - Carrier Performance 59TP5A Series Product Data

100 series boost two-stage 4-way multipoise condensing
Table of Contents

Advertisement

Heating Capacity and Efficiency
High
Heat
Input
Low
Heat
High
Heat
Output
Low
Heat
Efficiency
AFUE % (ICS)
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recom-
mended)
Transformer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Maximum Inlet
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections

SPECIFICATIONS

040-10
(BTUH)
40,000
(BTUH)
26,000
(BTUH)
39,000
(BTUH)
25,000
96.5
40 - 70
High Heat
(22 - 39)
30 - 60
Low Heat
(17 - 33)
040-10
Heating
0.10
Cooling
0.5
High Heat
695
Low Heat
590
Cooling
925
400 CFM/ton
2
350 CFM/ton
2.5
1/2
6.8
in.
11 x 7
KGAWF1606UFR
040-10
Volts-Hertz-
Phase
Min-Max
Amps
7.5
Amps
10.3
AWG
14
Feet
36
(M)
(11.0)
Amps
15
Heating
Cooling
040-10
2
Manufacturer
Minimum Inlet
Gas pressure
(in. wc)
Gas pressure
(in. wc)
165
060-14
080-16
60,000
80,000
39,000
52,000
58,000
78,000
38,000
50,000
96.3
96.2
40 - 70
40 - 70
(22 - 39)
(22 - 39)
30 - 60
30 - 60
(17 - 33)
(17 - 33)
060-14
080-16
0.12
0.15
0.5
0.5
1000
1360
785
1095
1505
1610
3.5
4
4
4.5
Electronically Commutated Motor (ECM)
3/4
3/4
8.4
8.4
600 - 1200
5
11 x 8
11 x 8
Factory Supplied Media Cabinet
Field Supplied Filter
KGAWF1306UFR
KGAWF1306UFR
KGAWF1406UFR
060-14
080-16
115-60-1
104-127
9.2
9.2
12.4
12.4
14
14
29
29
(8.8)
(8.8)
15
15
40 VA
24.3 VA
34.6 VA
060-14
080-16
1/2" - NPT
3
4
White Rogers
4.5
13.6
KGANP51012SP
KGAPN43012SP
not approved for MH use
Silicon Nitride
180
170
Adjustable: 90, 120, 150, 180 seconds
90 seconds
none
Com 24V, R, W/W1, G, Y/Y2, DHUM, Y1, W2
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
3
080-20
100-20
80,000
100,000
120,000
52,000
65,000
78,000
97,000
117,000
51,000
63,000
96.7
96.1
40 - 70
40 - 70
(22 - 39)
(22 - 39)
(22 - 39)
30 - 60
30 - 60
(17 - 33)
(17 - 33)
(17 - 33)
080-20
100-20
0.15
0.20
0.5
0.5
1360
1700
1055
1325
2015
2110
5
5
5.5
6
1
1
10.9
10.9
11 x 10
11 x 10
KGAWF1406UFR
KGAWF1506UFR
080-20
100-20
11.7
11.8
15.5
15.6
12
12
37
36
(11.3)
(11.0)
20
20
080-20
100-20
4
5
200
180
120-22
78,000
76,000
96.7
40 - 70
30 - 60
120-22
0.20
0.5
2125
1610
2055
5
6
1
10.9
11 x 11
120-22
11.8
15.6
12
36
(11.0)
20
120-22
6
160

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents