Gas Supply - Empire Comfort Systems BVD34FP Installation Instructions And Owner's Manual

The keystone "b" vent zero clearance gas fireplace
Table of Contents

Advertisement

Checking Manifold Pressures
Both Propane and Natural gas valves have a built-in pressure
regulator in the gas valve. Natural gas models will have a manifold
pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 4.5" w.c.
(1.120kPa) for the purpose of input adjustment to a maximum of
14.0" w.c. (3.484kPa). Propane gas models will have a manifold
pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 10.8" w.c.
(2.68kPa) for the purpose of input adjustment to a maximum of
14.0" w.c. (3.484kPa).
BURNER ASSEMBLY
PIEZO
IGNITER
SLIDING
VALVE ACCESS
COVER
22679-1-0408
GAS SUPPLY (CONT)
Figure 8
FROM FRONT OF
APPLIANCE TO
GAS LINE HOLE
BVD34 SERIES - 10"
BVD,P (36,42) - 13 ½"
Figure 7
REAR TAB (BURNER BASE)
LOCATIONS
FLEXIBLE GAS CONNECTOR
GAS SUPPLY LINE
FIREBOX BOTTOM
CUTOUT ACCESS
GAS LINE HOLE
3 ½"