Operating the Temperature Control System
Water Temperature Adjustment
The water temperature setting can be adjusted from 55°F
to 155°F.
Turn the Gas Control/Temperature Knob to the
desired setting/temperature. See Figure 22 on page 20.
NOTE: The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
Operating Modes and Settings
•
Standard Mode - The controller adjusts the water heater
to maintain the temperature set by the user.
•
Vacation Setting - The Vacation Setting (VAC) sets
the controller at approximately 55°F. This setting is
recommended when the water heater is not in use for a
long period of time. This effectively turns the controller
temperature setting down to a temperature that prevents
the water in the water heater from freezing while still
conserving energy.
LIST OF STATUS CODES ARE SHOWN
AT TOP OF GAS CONTROL VALVE / THERMOSTAT.
VAC
FIGURE 22B.
Status Light Codes
Normal Flashes:
•
0 Flashes Indicates Control Off/Pilot Out.
•
1 Flash Indicates Normal Operation.
•
Continuous Light indicates the gas control valve/thermostat
is shutting down.
Diagnostic Flashes: If the water heater is not working, look for
the following diagnostic flashes after lighting the pilot.
2 Flashes
Indicates thermopile voltage is low.
4 Flashes
Indicates overheat failure.
5 Flashes
Indicates water temperature sensor failure.
7 Flashes
Indicates electronic control failure.
8 Flashes
See "Status Light Code Troubleshooting Chart."
9 Flashes
Indicates chamber temperature sensor circuit
is open or shorted.
10 Flashes
Indicates an LDO occurrence was detected in
the combustion chamber (contaminants).
STATUS LIGHT