Operating
the Temperature
Control
System
Water
Temperature
Adjustment
The water
temperature
setting
can be adjusted
from 55°F
to 155°F.
Turn the Gas Control/Temperature
Knob to the
desired setting/temperature.
See Figure 22 on page 20.
NOTE: The temperatures
indicated are approximates.
The
actual temperature of the heated water may vary.
Operating
Modes
and Settings
Standard Mode - The controller adjusts the water heater
to maintain the temperature set by the user.
Vacation
Setting
- The Vacation
Setting
(VAC) sets
the controller
at approximately
55°F. This
setting
is
recommended
when the water heater is not in use for a
long period of time.
This effectively
turns the controller
temperature
setting down to a temperature
that prevents
the water
in the water
heater from freezing
while still
conserving energy.
Status
Light Codes
Normal Flashes:
0 Flashes
Indicates Control Off/Pilot Out.
1 Flash
Indicates Normal Operation.
Continuous Light indicates the gas control valve/thermostat
is shutting down.
Diagnostic
Flashes:
If the water heater is not working, look for
the following diagnostic flashes after lighting the pilot.
2 Flashes
4 Flashes
5 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
Indicates thermopile voltage is low.
Indicates overheat failure.
Indicates water temperature sensor failure.
Indicates electronic control failure.
See "Status Light Code Troubleshooting
Chart."
Indicates chamber temperature
sensor circuit
is open or shorted.
Indicates an LDO occurrence
was detected
in
the combustion chamber (contaminants).
LIST OF STATUS CODES ARE SHOWN
AT TOP OF GAS CONTROL VALVE / THERMOSTAT.
STATUS LIGHT
FIGURE 22B.
21