Chimney Connection - Napoleon XIR4-1N Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

3.2

CHIMNEY CONNECTION

Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 3" (76.2mm) diameter liner for intake and one 3" (76.2mm) diameter liner for exhaust. The minimum
and maximum vent lengths are 10 feet (3.1m) and 35 feet (10.7m) respectively.
Recommended kits come in 3 lengths:
While the liners must be continuous from the appliance to the chimney cap, to
achieve the needed length, they may be coupled, using an approved coupler
and sealant.
We recommend that exhaust vents that pass through unheated spaces,
such as tall exterior chimneys, be wrapped in a protective sleeve to minimize
condensation and reverse fl ow symptoms. See Trouble Shooting for details.
This appliance is approved for use with a 3" (76.2mm) exhaust and air intake.
A.
OUTSIDE: Slip the one end of a liner a minimum of 2" (50.8mm)
over the sleeve of the air terminal. Secure using 3 screws. Then
seal the joint and screw heads with high temperature sealant. Repeat with the other liner.
NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the
exhaust liner being connected to the intake collar at the appliance.
B.
Gently stretch the liners to the
required lengths and insert into
the chimney. Trim and fi t the
fl ashing plate to suit the chimney
termination. Place the air terminal
onto the top of the chimney.
Make weather tight by sealing
with caulking (not supplied).
Fasten to the chimney with
screws and plugs (not supplied).
C.
INSIDE: Remove the securing
screw from the front of the vent
mounting plate. Pull the vent
mounting plate only, back into
the track, to the front stop. Start
the slider back into position. Re-
secure the screw. The appliance
may now be pushed into its
fi nal position inside the wood
burning appliance, and the screw
tightened until the slider has
been pulled tight to the front stop.
D.
Route the fl ex liners through
the slider. Attach and secure
the liners to the vent mounting plate using the same procedure as before, ensuring that the marked
exhaust liner is attached to the exhaust collar.
2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT
GDI-325KT
GDI-335KT
HIGH TEMP
SEALANT
2" (50.8mm)
OVERLAP
VENT KIT 20FT (6.1m)
VENT KIT 25 FT (7.6m)
VENT KIT 35 FT (10.7m)
3" (76.2mm)
LINERS
SLIDER
MOUNTING
PLATE
EXHAUST
FLASHING
PLATE
2" (50.8mm)
OVERLAP
EXHAUST
SEALANT
INTAKE
HI-TEMP
VENT MOUNT
ASSEMBLY
INTAKE
SECURING
SCREW
W415-1194 / 03.04.13
9
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xir4-1p

Table of Contents