Specifications

Model
Volume [L]
Power [W]
Voltage/Frequency [V/Hz]
Actual Stdg. Loss [kWh/24h/45°C diff.]
Max. Stdg. Loss [kWh/24h/45 C diff.]
[as per IS 2082:1993 amended in 2002]
Reheating Time for 35°C rise [in min]
Temperature range [°C]
Rated water pressure
Inlet/Outlet connections [Inch]
Dimensions
Model
HSE-SBS
-015
A [mm]
373
B1 [mm]
373
B2 [mm]
405
C [mm]
337
Part Descriptors
1
Outlet
2
Inlet
3
Safety Valve*
4
Wired Remote
5
Decorative Front Panel
6
Front Jacket
7
Back Jacket
8
Anode
9
Heating Element
10
Tank
11
Installation Bracket
12
PU Insulation
13
Thermal Cutout
Caution: *Safety valve has been factory fit with the water heater and set at 0.8 MPa
(8 Bar) rated pressure.
Warning: Do not tamper or detach the safety valve from the water heater.
o
2
N/cm
Water head (metres)
HSE-SBS
-025
444
444
483
B2 B1
371
12
11
10
9
8
7
HSE-SBS-015
15
2000
~230/50
0.560
1.138
18
25-75
80
80
½
A
1
2
C
1
HSE-SBS-025
25
2000
~230/50
0.690
1.386
29
25-75
80
80
½
5
HE ATING
C
3
ON/OFF
6
13
SET
2kW
kWh
ENERGY
METER
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hse-sbs-025