Installation and User Guide

4. Technical Settings

4.1 Advanced menu

Deactivate/activate automatic daylight saving time.
dS
Adjust to radiator/room
Pb
Deactivate/activate intelligent control (forecast)
Fo
Information about horizontal or vertical orientation (0 = horizontal, 90 = vertical)
Or

4.2 Deactivating automatic daylight saving time

Select function menu
Select advanced menu
Select dS
Deactivate feature
1 = automatic daylight saving time (default setting).
0 = no automatic change.

4.3 Adjusting to radiator/room

2 is the factory setting.
1 is used if the radiator appears oversized for the room.
3 is used if the radiator appears undersized for the room.
Select function menu
Select advanced menu
Select Pb
Select adjustment
The frequency of heat adjustment varies for 1, 2 and 3.

4.4 Deactivating intelligent control

The thermostat's intelligent control (forecast) ensures that the desired temperature is reached by a given time.
Select function menu
Select advanced menu
Select Fo
Deactivate forecast
1 = forecast is activated (default setting).
0 = forecast is deactivated.
Danfoss Heating Solutions
living eco® Electronic Radiator Thermostat
Press and hold
for 3 sec.
Press both buttons
Select dS by pressing . Confirm using
Press , 0 flashes. Confirm using
Press and hold
for 3 sec.
Press both buttons
Select Pb by pressing . Confirm using
Select 1, 2 or 3 using
Press and hold
for 3 sec.
Press both buttons
Select Fo by pressing . Confirm using
1 flashes. Select 0 using . Confirm using
VIIDB102
flashes.
for 3 sec.
. 1 flashes.
.
flashes.
for 3 sec.
.
. Confirm using
.
flashes.
for 3 sec.
.
.
13