Shutter Adjustment; Leg Leveling System; Installing The Baffl E - Tiara I-B; Brick Installation - Tiara Ii-B - Heat & Glo TIARAI-BK-B Owner's Manual

Direct vent room heater installation and operation
Hide thumbs Also See for TIARAI-BK-B:
Table of Contents

Advertisement

D. Shutter Adjustment
OPEN
Figure 8.11
The shutter is located on the underside of the
appliance, on the right side. To adjust the shutter, loosen
the wingnut. Retighten the wingnut after adjustment.
Moving the shutter bolt to the right closes the shutter. Moving
the shutter bolt to the left, will open the shutter. Opening the
shutter causes flames to become shorter and blue. Closing
the shutter creates taller orange/yellow flames.
NOTE: Do not close so much as to cause a sooty flame.
Improper adjustment can cause sooting in the firebox and/or
on the outside of a house with a horizontal termination.
After adjustment, tighten nut to lock in place.
E. Leg Leveling System
Figure 8.12
Thread Allen bolts through nuts until fl ush. The
Allen bolts and nuts are included in the component pack inside
the appliance fi rebox.
Figure 8.13
Slide assembled nuts and bolts into the slots on
the legs with the nuts on the bottom.
Page 32
CLOSE
Figure 8.14
up and down to desired level.
F. Installing the Baffl e - Tiara I-B
Figure 8.15
and right sides. Centering baffl e on retainers, ensuring that
the bevelled edge is toward the back of the fi rebox.
G. Brick Installation - Tiara II-B
Figure 8.16
fl ush and centered against back of fi rebox.
Heat & Glo · Tiara I B & Tiara II B · 7010-149L
Use a 5/32 in. (4mm) Allen wrench to adjust legs
BAFFLE RETAINERS
Position baffl e on top of baffl e retainers on left
NOTE: The brick supplied with the Tiara II-B is NOT an
optional accessory.The brick must be installed for safe and
proper operation.
I
nstall rear panel by placing it behind the log pins
BAFFLE
REAR PANEL
November 14, 2007

Advertisement

Table of Contents