3 Fit the front cover.
4 Set the cutting height control to one of the positions 1-7

Checking the blades

To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades' attachment screws are tight.
Rider 11 C, 13 C, 16 C, 16 AWD
Put the unit in the service position, see Service position
for the cutting unit.
Rider 11 R
Lift up the cutting unit
Set the cutting height control in the highest position.
32 –
English
Maintenance
IMPORTANT INFORMATION
Replacing or sharpening the blades should be conducted
by an authorised service workshop.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the servicing dealer judge
whether the blade can be repaired/ground or must be
discarded.
!

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
1 Put the unit in the service position, see Service position
for the cutting unit.
2 Loosen the knob holding the BioClip-plug and remove the
plug.
3 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
WARNING! If the blades are cracked,
whether caused by poor repair or other
damage, they could break while being used.
The risk increases if the blades are poorly
balanced.