OptiOnal gaS line

inStallatiOn
Continued
CAUTION: All gas piping
and connections must be tested
for leaks after the installation
is completed. After ensuring
that the gas valve is on, apply
soap and water solution to all
connections and joints. Bubbles
forming show a leak. Correct
all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK
IS DETECTED. LEAK TESTING
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON.
WARNING: Do not oper-
ate an unvented gas log set in
this fireplace with the chimney
removed.
If you install a decorative gas appliance (vented
gas log), the decorative gas appliance must comply
with the Standard for Decorative Gas Appliance
for Installation in Solid Fuel Burning Fireplaces,
ANS Z21.60, Z21.84 or RG 2-72 and shall also be
installed in accordance with the National Fuel Gas
Code, ANSI 7223NFPA 54 latest edition.
WARNING: If the fireplace
has been used for wood burning,
the firebox and chimney must be
cleaned of soot, creosote and
ashes be a qualified chimney
cleaner. Creosote will ignite if
heavily heated.
WARNING: When using a
decorative vented gas log, the
damper must be removed or
permanently locked in the fully
open position and the glass
doors must be in the fully open
position.
117541-01B
Outside of
Fireplace
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Figure 18 - Gas Line Knockout
Outside of
Fireplace
Gas
Line
Conduit
Repack
Insulation
Figure 19 - Gas Line Installation

bRick inStallatiOn

Installation of brick should be
done after the fireplace is placed
in a permanent location.
The brick housing panels are already installed in
the firebox. Each housing is stamped with a letter
(full size bricks are not stamped). These letters will
help identify the brick when installing. It is impor-
tant to install these bricks exactly as instructed.
Press the brick firmly into the brick housing until
it snaps. The groove line on the side of the brick
will come in contact with the flange on the brick
housing. This secures the brick into the housing.
See Figure 20 on page 14.
The bricks are packaged in four separate boxes.
These boxes are labeled by sections of the fire-
box.
Box #1 - Hearth Panel
Box #2 - Rear Panel
Box #3 - Left or Right Panel
Box #4 - Left or Right Panel
www.desatech.com
Side
Firebrick
Finished
Side
Remove
Knockout
1/2" Dowel
Refractory
Knockout
Plug
Side
Firebrick
Finished
Incoming
Side
1/" Black
Iron Pipe
Seal
Opening
with
Refractory
Cement
Provide Enough Threaded
End for Fitting Connection
13