Optional Gas Line Installation - Desa V)C36 Owner's Operation And Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

opTIonal gas lIne InsTallaTIon

Gas line hook up should be done by your
supplier or a qualified service person.
Note: Before you proceed, make sure your
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refracto-
ry or firebrick wall located above refractory
hearth floor. Knockout indentation must
be firmly tapped with any solid object,
such as a 1/2" dowel, until it is released.
Remove fragmented portions of refractory
(see Figure 21).
2. Remove gas line cover plate located on
either side of fireplace and pull out insu-
lation from gas line conduit sleeve. Save
insulation for reuse.
3. Run a 1/2" black iron gas line into fireplace
through rear at gas line conduit sleeve (if
using a raised platform, add height). Provide
sufficient gas line into fireplace chamber for
fitting connection (see Figure 22).
Note: Secure incoming gas line to wood
framing to provide rigidity for threaded end.
4. Repack insulation around gas line and into
sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement. Install gas appliance or cap off
gas line if desired.
CAUTION: All gas piping and
connections must be tested for
leaks after installation is com-
pleted. After ensuring that gas
valve is on, apply soap and water
solution to all connections and
joints. Bubbles forming show a
leak. Correct all leaks at once.
DO NOT USE AN OPEN FLAME
FOR LEAK TESTING AND DO
NOT OPERATE ANY APPLIANCE
IF A LEAK IS DETECTED. LEAK
TESTING SHOULD BE DONE
BY A QUALIFIED SERvICE
PERSON.
Note: A DESA Heating, LLC hood must be
installed when using an unvented gas log set
(see Accessories on page 18).
107777-01E
WARNING: Do not operate an
unvented gas log set in this fire-
place with chimney removed.
If you install a decorative gas appliance (vent-
ed gas log), decorative gas appliance must
comply with the Standard for Decorative Gas
Appliance for Installation in Solid Fuel Burning
Fireplaces, ANS Z21.60, Z21.84 or RG 2-72
and shall also be installed in accordance with
the National Fuel Gas Code, ANSI 7223NFPA
54 latest edition.
of damaging the fireplace mate-
rials and increasing the risk of
spreading a fire, do not use the
fireplace to cook or warm food.
Outside of
Fireplace
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Figure 21 - Gas Line Knockout
Outside of
Fireplace
Gas
Line
Conduit
Repack
Insulation
Figure 22 - Gas Line Installation
www.desatech.com
WARNING: To avoid the risk
Incoming
1/2" Black
Iron Pipe
Seal
Opening
with
Refractory
Cement
Provide Enough Threaded
End for Fitting Connection
Side
Firebrick
Finished
Side
1/2" Dowel
Refractory
Knockout
Plug
Side
Firebrick
Finished
Side
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents