Desa UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE Owner's Operating & Installation Manual

Unvented (vent-free) propane/lp gas fireplace, variable manually controlled models and thermostatically controlled “b” models with split oak logs

Advertisement

UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE
This appliance may be installed in an aftermarket* manufactured (mobile) home,
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
OWNER'S OPERATION AND INSTALLATION MANUAL
Variable
Manually-
Controlled
Models and
Thermostatically-
Controlled
"B" Models
with
Split Oak Logs
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
DESA INTERNATIONAL
where not prohibited by state or local codes.
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQQQQQ
QQQQQQ
QQQQQQQQQQ
QQQQQQ
QQQQQQQQQQ
Save this manual for future reference.
QQQ
QQQ
QQQ
Shown with optional
cabinet mantel, hearth
base, and trim
accessories.
WARNING: Improper installation,
adjustment, alteration, service,
or maintenance can cause injury
or property damage. Refer to this
manual for correct installation
and operational procedures. For
assistance or additional infor-
mation consult a qualified in-
staller, service agency, or the
gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to Air for
Combustion and Ventilation sec-
tion in this manual.
®

Advertisement

Table of Contents
loading

Summary of Contents for Desa UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE

  • Page 1 DESA INTERNATIONAL UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer OWNER’S OPERATION AND INSTALLATION MANUAL Variable QQQQQQ Manually-...
  • Page 2: Table Of Contents

    CONTENTS SECTION PAGE Safety Information ....................2 Product Identification ..................... 4 Local Codes ......................5 Unpacking ....................... 5 Product Features ..................... 5 Air for Combustion and Ventilation ............... 6 Installing ......................... 9 Check Gas Type ....................9 Electrical Hookup .................... 9 Assembling and Attaching Brass Trim ............
  • Page 3 WARNINGS Continued SAFETY WARNING ICON G 001 WARNING: Any change to this fireplace or its controls can be dangerous. INFORMATION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Continued 2.
  • Page 4: Product Identification

    PRODUCT Crossover Log Rear Log IDENTIFICATION Top Middle Log Left Front Branch Rear Burner Front Burner Bottom Right Front Middle Log Branch Base Assembly Figure 1 - Log Base Assembly, Split Oak Set Top Louver Top Outer Assembly Casing Firebox Hood Firebox Support...
  • Page 5: Local Codes

    LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
  • Page 6: Air For Combustion And Ventilation

    AIR FOR WARNING WARNING ICON G 001 COMBUSTION This heater shall not be installed in a confined space unless provisions are pro- vided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. VENTILATION Today’s homes are built more energy efficient than ever.
  • Page 7 DETERMINING AIR FLOW FOR FIREPLACE LOCATION AIR FOR Determining if You Have a Confined or Unconfined Space COMBUSTION Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 8 AIR FOR WARNING WARNING ICON G 001 COMBUSTION If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3. VENTILATION VENTILATION AIR Continued...
  • Page 9: Installing

    INSTALLING NOTICE A qualified service person must install fireplace. Follow all local codes. WARNING WARNING ICON G 001 Never install the fireplace • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace •...
  • Page 10: Assembling And Attaching Brass Trim

    ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM INSTALLING (Included with Mantel Accessory) Continued IMPORTANT: If you are recessing the firebox in a wall, do not attach brass trim at this time. See page 13. Note: The instructions below show assembling and attaching brass trim to fireplace. 1.
  • Page 11: Installation Clearances

    INSTALLATION CLEARANCES INSTALLING Continued WARNING WARNING ICON G 001 Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. Carefully follow the instructions below. This will ensure safe installation. Minimum Wall and Ceiling Clearances (see Figure 8) A.
  • Page 12 3. Install gas piping to fireplace location. This installation includes an approved flexible gas INSTALLING line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, Continued page 15.
  • Page 13: Built-In Fireplace Installation

    9. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, INSTALLING page 17. Continued 10.If blower is installed, route blower electrical cord through access holes in either side of fire- place. Bushing may be moved if necessary. Plug electrical cord into electrical outlet. Note: 11.Carefully insert fireplace into cabinet mantel.
  • Page 14 If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height INSTALLING is 33" which is the same as the wall opening above. Continued 39 3/8" 27 7/8" 35 1/2" 55 5/8" Figure 14 - Rough Opening for Installing in Corner 2.
  • Page 15: Installing Gas Piping To Fireplace Location

    Mantel Clearances for Built-In Installation INSTALLING If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening. Continued Mantel Shelf 10" Underside of 8" Mantel Shelf 6" " All minimum distances are in inches 1 /2 1 /2...
  • Page 16 The installer must supply an external regulator. The external regulator will reduce incoming gas INSTALLING pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external Continued regulator with the vent pointing down as shown in Figure 17.
  • Page 17: Connecting Fireplace To Gas Supply

    A.G.A. Design-Certified Manual INSTALLING Shutoff Valve with 1/8" NPT Tap* Continued Approved Flexible Gas Line From Gas Meter (5" W.C. to 10.5" W.C. 3" Minimum Pressure) Sediment Trap Tee Joint Pipe Nipple Figure 18 - Gas Connection * Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 34.
  • Page 18: Checking Gas Connections

    3. Route flexible gas line from manual shutoff valve to fireplace. Route flexible gas supply line INSTALLING through one of the access holes. Continued NOTICE Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace. The flexible gas supply line connection to the manual shutoff valve should be accessible.
  • Page 19 Test Pressures Equal To or Less Than 1/2 PSIG INSTALLING 1. Close manual shutoff valve (see Figure 21). Continued 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3.
  • Page 20: Installing Logs

    INSTALLING LOGS (Split Oak Design Models) INSTALLING Continued WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed.
  • Page 21 INSTALLING 4. Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 27).
  • Page 22: Operating Fireplace (Thermostat-Controlled Models)

    OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING FIREPLACE WARNING Thermostat- WARNING ICON G 001 If you do not follow these instructions exactly, a fire or explosion may result Controlled Models causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 23: To Turn Off Gas To Appliance

    6. Continue pressing control knob in. Press and release ignitor button. This will light pilot. OPERATING The pilot is attached to the front burner. If needed, keep pressing ignitor button until FIREPLACE pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for Thermostat- repairs.
  • Page 24: Operating Fireplace (Manually-Controlled Models)

    OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING FIREPLACE WARNING Manually-Controlled WARNING ICON G 001 If you do not follow these instructions exactly, a fire or explosion may result Models causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 25 6. Continue pressing control knob in. Press and release ignitor button. This will light OPERATING pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button FIREPLACE until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for Manually-Controlled repairs.
  • Page 26: Inspecting Burners

    OPERATING BLOWER OPERATION FIREPLACE WARNING VSGF28PTB/ This fireplace has a three-prong, grounded electrical plug. This plug helps protect CSGF28PTB Models you against electrical shock. Only connect plug to a properly grounded, three- prong receptacle. Do not cut or remove the grounding prong from this plug. Locate the blower switch by opening lower louver on fireplace.
  • Page 27 FRONT BURNER FLAME PATTERN INSPECTING Figure 35 shows correct front burner flame pattern. Figure 36 shows incorrect front burner BURNERS flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame. Continued WARNING WARNING ICON G 001 If front burner flame pattern shows yellow tipping, your fireplace could produce increased levels of carbon monoxide.
  • Page 28: Cleaning And Maintenance

    CLEANING WARNING WARNING ICON G 001 Turn off fireplace and let cool before cleaning. MAINTENANCE CAUTION WARNING ICON G 001 You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person.
  • Page 29 OBSERVED POSSIBLE TROUBLE- PROBLEM CAUSE REMEDY SHOOTING When ignitor button is 1. Gas supply turned off or 1. Turn on gas supply or open Continued pressed, there is spark manual shutoff valve manual shutoff valve at ODS/pilot but no closed ignition 2.
  • Page 30 OBSERVED POSSIBLE TROUBLE- PROBLEM CAUSE REMEDY SHOOTING Delayed ignition of one 1. Manifold pressure is too 1. Contact local propane gas or both burners company Continued 2. Burner orifice(s) clogged 2. Clean burner(s) (see Cleaning and Maintenance, page 28) or replace burner orifice(s) 3.
  • Page 31 TROUBLE- WARNING WARNING ICON G 001 SHOOTING If you smell gas • Shut off gas supply. Continued • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. •...
  • Page 32: Technical Service

    You may have further questions about installation, operation, or troubleshooting. TECHNICAL If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG SERVICE (1-800-337-2564). When gas pressure is too low SERVICE • pilot will not stay lit HINTS • burners will have delayed ignition •...
  • Page 33: Specifications

    Btu (Low/High) 20,000/28,000 SPECIFICATIONS Type Gas Propane/LP Gas Only Ignition Piezo Manifold Pressure 7.9" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum 11" Shipping Weight 128 lbs. Thermostat Model 122 lbs. Manual Model CAUTION: Label all wires prior to disconnection when servicing controls. Wiring WIRING errors can cause improper and dangerous operation.
  • Page 34: Accessories

    Purchase these fireplace accessories from your local dealer. If they can not supply these accesso- ACCESSORIES ries, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the address listed on the back page of this manual. QQQQQQ QQQQQQ CABINET MANTEL...
  • Page 35 ACCESSORIES Continued QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ CORNER MANTEL GM200F Series - Walnut Finished GM201U Series - Unfinished Shown with optional laminate mantel trim accessory. Dimensions (WxHxD): 60-7/8" x 48-3/4" x 34-5/8" QQQQ QQQQ QQQQ QQQQ QQ QQ QQ QQQQQ QQQQ...
  • Page 36: Illustrated Parts Lists

    ILLUSTRATED PARTS BREAKDOWN Log Base Assembly Variable Manually- Controlled Models VSGF28PV 7-1 7-2 103415...
  • Page 37 This list contains replaceable parts used in your fireplace. When ordering parts, PARTS LIST follow the instructions listed under Replacement Parts on page 32 of this manual. Log Base Assembly Variable Manually- Controlled Models VSGF28PV PART NUMBER DESCRIPTION QTY. 103580-01 Left Front Log (#1L) 103580-02 Right Front Log (#1R)
  • Page 38 ILLUSTRATED PARTS BREAKDOWN Log Base Assembly Thermostat- Controlled Models VSGF28PTB CSGF28PTB 7-1 7-2 103415...
  • Page 39 This list contains replaceable parts used in your fireplace. When ordering parts, PARTS LIST follow the instructions listed under Replacement Parts on page 32 of this manual. Log Base Assembly Thermostat- Controlled Models VSGF28PTB CSGF28PTB PART NUMBER DESCRIPTION QTY. 103580-01 Left Front Log (#1L) 103580-02 Right Front Log (#1R)
  • Page 40 VSGF28PTB ILLUSTRATED CSGF28PTB PARTS BREAKDOWN Fireplace 103415...
  • Page 41 This list contains replaceable parts used in your fireplace. When ordering parts, PARTS LIST follow the instructions listed under Replacement Parts on page 32 of this manual. Fireplace VSGF28PTB/CSGF28PTB PART NUMBER DESCRIPTION QTY. 101357-01 Top Outer Casing 103207-01 Outer Casing 102758-01CK Right Front Side 102759-01CK...
  • Page 42 VSGF28PV ILLUSTRATED PARTS BREAKDOWN Fireplace 103415...
  • Page 43 This list contains replaceable parts used in your fireplace. When ordering parts, PARTS LIST follow the instructions listed under Replacement Parts on page 32 of this manual. Fireplace VSGF28PV PART NUMBER DESCRIPTION QTY. 101357-01 Top Outer Casing 103207-01 Outer Casing 102758-01CK Right Front Side 102759-01CK...
  • Page 44: Warranty Information

    WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.

This manual is also suitable for:

Vsgf28ntbCsgf28ntbVsgf28ptbCsgf28ptbVsgf28pv