Optional Gas Line Installation - Desa PN36-A Owners Manual And Installation Manual

Peninsula woodburning fireplace
Table of Contents

Advertisement

oPTional gas line
insTallaTion
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
NOTICE: Before you proceed, make sure your
gas supply is turned off.
A gas line may be installed for the purpose
of installing a vented or vent-free decorative
gas appliance available through your local
distributor. Use only gas piping approved
by local codes. When installing a gas line, a
shutoff valve designed for installation outside
the appliance is recommended.
The gas pipe is intended for connection to
a decorative gas appliance that operates
using natural or propane/LP gas only. This
appliance must have an automatic shutoff
device and must comply with the Standard
for Decorative Gas Appliances for Installa-
tion in Vented Fireplace, ANSI Z21.60-1990.
ONLY UNVENTED GAS LOG SETS WHICH
HAVE BEEN FOUND TO COMPLY WITH
THE STANDARD FOR UNVENTED ROOM
HEATERS, ANSI/IAS/AGA Z21.11.2, ARE TO
BE INSTALLED IN THIS FIREPLACE.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refrac-
tory or firebrick wall located approximately
2" above refractory hearth floor. Knockout
indentation must be firmly tapped with any
solid object such as a 1/2" dowel until it is
released. Remove fragmented portions of
refractory (see Figure 29).
2. Remove gas line cover plate located on
rear of fireplace and pull out insulation
from gas line conduit sleeve. Save insula-
tion for reuse.
3. Run gas line into fireplace through the rear
at 11
/
" from floor and through gas line
1
4
conduit sleeve (if using a raised platform,
add height). Provide sufficient gas line into
fireplace chamber for fitting connection
(see Figure 30). Note: Secure incoming
gas line to wood framing to provide rigidity
for threaded end.
4. Repack insulation around gas line and into
sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install gas appliance or cap off
gas line if desired.
12
and connections must be tested
for leaks after the installation
is completed. After ensuring
that the gas valve is on, apply
soap and water solution to all
connections and joints. Bubbles
forming show a leak. Correct
all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK
IS DETECTED. LEAK TESTING
ShOULD BE DONE BY A QUALI-
FIED SERVICE PERSON.
ate an unvented gas log set in
this fireplace with the chimney
removed.
Outside of
Fireplace
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Figure 29 - Gas Line Knockout
Outside of
Fireplace
Gas
Line
Conduit
Repack
Insulation
Figure 30 - Gas Line Installation
www.desatech.com
CAUTION: All gas piping
WARNING: Do not oper-
Remove
Knockout
Incoming
1/2" Black
Iron Pipe
Seal
Opening
with
Refractory
Cement
Provide Enough Threaded
End for Fitting Connection
Side
Firebrick
Finished
Side
1/2" Dowel
Refractory
Knockout
Plug
Side
Firebrick
Finished
Side
115607-01C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vpn36-a

Table of Contents