Optional Gas Line Installation - Desa F48H Owner's Operation And Installation Manual

Plantation 48" wood burning fireplace with herringbone masonry
Table of Contents

Advertisement

4" Min.
4" Min.
Figure 16 - Multiple Chase Installation
10 FOOT RULE
All flue gas outlet chimney terminations must
extend a minimum of 3 feet in height above
the highest point where it passes through roof
and must be at least  feet above highest point
of roof that is within a horizontal distance of
10 feet (see Figure 17).

optional gas line installation

Gas line hook up should be done by your
supplier or a qualified service person.
Note: Before you proceed, make sure your
gas supply is turned off. Use only a 1/2" black
iron pipe and appropriate fittings.
1. Remove gas line cover plate located on
either side of fireplace and pull out insu-
lation from gas line conduit sleeve. Save
insulation for reuse. Replace screws.
2. Run a 1/2" black iron gas line into fire-
place through rear at gas line conduit
sleeve (if using a raised platform, add
height). Provide sufficient gas line into
fireplace chamber for fitting connection
(see Figure 18).
Note: Secure incoming gas line to wood
framing to provide rigidity for threaded
end.
10
Venting installation
Continued
18"
Min.
Typ.
www.desatech.com
10'
2' Min.
Figure 17 - 10 Foot Rule
FINISHING FIREPLACE
Combustible materials, such as wallboard,
gypsum board, sheet rock, drywall, plywood,
etc. may make direct contact with sides and
top around fireplace face. It is important that
combustible materials do not overlap face
itself. Brick, glass, tile or other noncombustible
materials may overlap front face provided
they do not obstruct essential openings like
louvered slots or any other opening. When
overlapping with a noncombustible facing
material, use only noncombustible mortar or
adhesive.
3. Repack insulation around gas line and into
sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install gas appliance or cap off
gas line if desired.
Outside of
Fireplace
Gas
Incoming
1/" Black
Line
Iron Pipe
Conduit
Repack
Insulation
Provide Enough Threaded
End for Fitting Connection
Figure 18 - Gas Line Installation
Level of
Flue Gas
Outlet
10'
3' Min.
2' Min.
Side
Firebrick
Finished
Side
Seal
Opening
with
Refractory
Cement
118116-01D
3' Min.