Figure 11. Interface Connections on a Rackmount Controller Module
10. Go to the next task.
End of Procedure

Installing the Drive Module

Tools and Equipment

v Antistatic wrist strap or other antistatic protection device
v screwdrivers
v all drive module FRUs
v Table or counter-top to hold FRUs

Instructions

Use this procedure to install a drive module on the support rails in a rackmount
cabinet. These instructions assume that you are following the "Cabinet Preparation
Task List" on page 43.
Attention: Electrostatic discharge can damage sensitive components. Use a
grounding wrist strap or other antistatic precautions before removing or handling
any components in the cabinet.
1. To reduce weight, remove the drive FRUs from the drive module, using
8. If applicable, attach secondary interface cables (Figure 11).
There is one RS-232 and one Ethernet connector for each controller. Attach
cables to these connections if you need to perform troubleshooting, special
configuration tasks or you are connecting the controller to a network RAID
storage Management PC.
9. Route and secure the Fibre Channel interface cables. If all the drive modules
are already installed and connected, then also route and secure the SCSI
interface cables.
Arrange the interface cables so they clear the vents on the back of the
controller module. Secure the cables with tie-wraps.
Figure 12 on page 50 and Figure 13 on page 51 as a guide.
Chapter 2. Installation And Removal Guide