Operation; Wiring Diagrams; Selector Switches - Hunter Set & Save 47250A Owner's Manual

Hunter owners manual programmable thermostat 47250a
Table of Contents

Advertisement

®

Wiring Diagrams

4-wire Heat/Cool System
Wallplate
Jumper
Terminals
Rh
G
Rc
X
Heat/Cool
Cool
Fan
24V Supply
Relay
Contactor
5-wire Heat/Cool System
Wallplate
No Jumper
Terminals
Rh
G
Rc
Fan
Cool 24V
Heat 24V
Relay
Supply
Supply
Single-stage Heat Pump System
Wallplate
Jumper
Terminals
G
Rc
Rh
Cool
X
Mode
Fan
Heat Pump
Relay
24V Supply
2-wire Heat Only System
Wallplate
Jumper
Terminals
Rh
G
Rc
X
X
Heat 24V or
Millivolt Supply
3-wire Heat Only System
Wallplate
Jumper
Terminals
Rh
G
Rc
X
Heat 24V
Fan
Supply
Relay
3-wire Cool Only System
Wallplate
Jumper
Terminals
Rh
G
Rc
X
Fan
Cool 24V
Cool
Relay
Supply
Contactor
X - No Connection
System
Selector
Y/O
W/B
Y1
X
Heat Relay
or Valve
System
Selector
Y/O
W/B
Y1
X
Heat Relay
Cool
or Valve
Contactor
System
Selector
Y1
Y/O
W/B
OR
Heat
Mode
Reversing
Compressor
Valve
Contactor
Connect to Proper Reversing
Valve Terminal. See Table A
System
Selector
Y/O
W/B
Y1
X
X
Heat Relay
or Valve
System
Selector
Y/O
W/B
Y1
X
X
Heat Relay
or Valve
System
Selector
Y/O
W/B
Y1
X
X

Selector Switches

In order for this thermostat to control your system, the system type must be specified by the
selector switches on the printed circuit board inside the thermostat.
Heating System Selector (HG - HE switch)
The factory position for this switch is in the "HG" position. Leave it in this position if you have
STD HP
a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat
and Fan come on as expected after installation. If the Fan operation is normal, leave it in the
"HG" position. If the Fan does not come on within a minute of the thermostat calling for heat,
change the switch position to "HE". The system selector has no effect in the cooling mode.
NOTE: "HG" position is for gas and most other systems. "HE" position is for certain
electric systems having a fan relay.
System Selector (STANDARD - HEAT PUMP switch)
The factory position for this switch is in the STD position. Leave it in this position if you have
ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat
Pump (no auxiliary or emergency heat source), then slide the switch to the HP position. Be sure
the reversing valve wire is connected to the correct terminal for your heat pump (Y/O) or (W/B).
STD HP
Auto Recovery selector (DISABLE / ENABLE)
Your thermostat is set from the factory with the Auto Recovery Feature enabled, which com-
plies with the EPA ENERGY STAR
switch to the DISABLE position.
STD HP
C˚ / F˚ Selection (Celcius / Fahrenheit)
Your thermostat is set for C˚ mode from the factory. To change to F˚ mode, follow these steps:
Press and hold the Up key.
Use a paper clip to press the reset key.
Once all the LCD segments turn on, release the Up key.
STD HP
NOTE: To return to C˚ mode, press the reset key with a paper clip. Do not press any
other keys during the reset process.
All programs and settings will be lost when pressing RESET.

OPERATION

Setting Day and Time
STD HP
STEP 1:
STD HP
day/time
®
Program. If you prefer to use normal recovery, slide the
DISABLE ENABLE
STD
Figure 7
The LCD will show this information when
batteries are first installed, or after the
Reset button is pressed. The temperature
will update after a few seconds.
During time and day setting mode, the
temperature and program displays will go
blank.
Example: Set the Thermostat to the current
time of 2:16 pm on Saturday. Refer to the
Steps below.
Press to enter time and day setting mode.
The current hour and the AM / PM indicator
will be flashing.
Press to change the Hour up or down to the
current hour.
Note the AM / PM indicator, as the display
will change at 12 AM and 12 PM.
4
Auto Recovery
(SW4)
System Selector
(SW5)
HP
Fan Option
(SW6)
M
AM
4
TEMP
M
AM
(Continued)