Maintenance; Service Position; Check Tire Pressure - Ariens 924119 Owner's/Operator's Manual

Sno-thro series
Table of Contents

Advertisement

Ariens Dealers will provide any service or adjustments
which may be required to keep your unit operating at
peak efficiency. Should engine service be required,
contact an Ariens dealer or an authorized engine
manufacturer's service center.
WARNING: AVOID INJURY. Read and
understand Maintenance and Service and
Battery Safety Rules in Safety section before
attempting any maintenance.

SERVICE POSITION

WARNING: Before tipping unit up onto
housing, remove fuel so no spills will occur
and remove battery (if equipped). Ensure unit
is secure and will not tip over during

maintenance.

Place unit in service position when required. Place unit
on a flat level surface. Tip unit forward onto front of
Impeller housing for service. Assure unit is secure and
will not tip over. Strap and clamp onto bench if needed.
MAINTENANCE SCHEDULE
The chart below shows the recommended
maintenance schedule that should be performed on a
regular basis. More frequent service may be required
due to working conditions (heavy loads, high ambient
temperatures, dusty conditions, or airborne debris).
MAINTENANCE SCHEDULE
Daily
Service Performed
Check Fasteners
Check Engine Oil
Change Engine Oil
Check Auger
Gearcase

Check Tire Pressure

General Lubrication
Battery Maintenance
Clean Engine
*
First Maintenance Only
CHECK FASTENERS
Make sure all hardware is tightened properly.
MAINTENANCE
Every
Every
Every
5 hrs.
25 hrs.
100 hrs.
*
CHECK ENGINE OIL
The engine crankcase oil should be checked every 5
hours of operation. Oil level MUST be maintained in
safe operating range on dipstick at all times or engine
damage will result (See Engine Manual).
Park unit on a level surface. Refer to Engine Manual for
detailed instructions.
CHANGE ENGINE OIL
Change oil after first 5 hours of operation, thereafter
change oil every 25 hours (more often if required).
Refer to Engine Manual for detailed instructions.
Run engine just prior to changing oil. Warm oil will flow
more freely and carry away more contamination.
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be maintained.
Gear cases are filled to the correct level at the factory.
Unless there is evidence of leakage, no additional
lubricant should be required. Check for evidence of
leakage every 25 hours of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 8). Lubricant must be
at least up to bottom of lubricant filler hole with
unit resting on a level-surface.
2. Add lubricant if required. Allow oil to drain to level
of plug and replace plug.
IMPORTANT: Use only Ariens special gear lubricant
L-2 (Part Number 00008000).
1
1. Auger Gearcase - Cast Iron
2. Oil Fill and Drain Plug
3. Auger Gearcase - Aluminum
CHECK TIRE PRESSURE
Maintain the unit tire pressure at a maximum 14 PSI
(97 kPa).
GB - 15
2
3
Figure 8
2
OS0620

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents