Heat & Glo 6000CLX-IPI-T Owner's Manual page 29

Fireplace
Hide thumbs Also See for 6000CLX-IPI-T:
Table of Contents

Advertisement

Top Vent - Vertical Termination (continued)
3. Match the amount of vertical you have in the system
with the chart to fi nd the appropriate position to set the
Flue Restrictor (see Figure 7.9).
TOP VENT
Vertical
NG
4 ft.
1-1
Restrictor
8 ft.
2-2
15 ft.
3-2
20 ft.
3-2
25 ft.
3-2
30 ft.
3-3
35 ft.
3-4
40 ft.
3-4
Figure 7.9
Note: If the DVP-2SL or DVP-SLP24 adapter is used with
SLP pipe, you MUST subtract one number from the table
above.
Example: Top vent 40 ft vertical with DVP pipe = 3-4
Top vent 40 ft vertical with SLP pipe = 2-3
Two Elbows
Figure 7.11
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09
REAR VENT
LP
NG
LP
No
No
No
Restrictor
Restrictor
No
1-2
1-1
Restrictor
3-2
2-2
1-2
3-2
3-2
3-2
3-2
3-2
3-2
3-3
3-3
3-3
3-4
3-4
3-3
3-4
3-4
3-4
V
2
H
1
4. Center the Flue Restrictor on vent and secure in place
by using two self-tapping screws (see Figure 7.10).
5. Reinstall the Exhaust Shield.
Figure 7.10
V
1
Elbow only
6 in.
152 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
V
+ V
+ H
1
2
1
*No specifi c restrictions on this value EXCEPT
V
+ V
+ H
cannot exceed 50 ft (15.2 m)
1
2
1
V
1
1
2
3
4 5
SETTING
1
2
3
4 5
H
Maximum
V
V
+ V
1
2
1
2 ft.
610 mm
*
*
6 ft.
1.8 m
*
*
11 ft.
3.4 m
*
*
16 ft.
4.9 m
*
*
20 ft.
6.1 m
*
*
= 50 ft. (15.2 m) Maximum
Min.
2
*
*
*
*
*
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents