Electrical Service And Repair; Junction Box Installation; Active Convection Blower Replacement - Heat & Glo RED60 Owner's Manual

Installation and operation
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

E. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
F. Junction Box Installation
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
1. Remove the one screw that secures the junction box
to the control tray panel.
2. Route the wire through the strain relief in the outer wrap
and down through the knockout located on top side of
the junction box. See Figure 12.7.
3. Make the connection inside the junction box to the 120V
wire. Connect green to the ground nut, black to black,
and white to white.
4. To reattach the junction box, insert one end of the
junction box in the slot provided and securely screw the
other end of the junction box to the control tray panel.
KNOCKOUT
KNOCKOUT
Figure 12.7 Junction Box Detail
In the event that the junction box may need to be ac-
cessed or installed after fi nish methods have been ap-
plied, access is possible by removing the valve assembly
(See Figure 11.2).
66
G. Active Convection Blower Replacement
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
1. Remove fi re screen door assembly and any external
2. Remove glass frame assembly by unlatching the
3. Locate the fan mount fastener on either the left or right
Figure 12.8 Fastener Location
4. Remove fastener with 1/4 inch nut driver as shown in
Figure 12.9 Remove Fastener
5. Slide fan forward slightly to release it from the fan mount
6. Locate blower power wires and unplug them from their
7. Remove blower from appliance. See Figure 12.10.
Heat & Glo • RED60 • 2159-900 Rev. B • 12/09
media or refractory from front of appliance.
four glass latches located at the bottom of the glass
frame.
side of the appliance. See Figure 12.8.
Figure 12.9.
housing.
locations. Note these positions for reinstallation.