Heat & Glo RED60 Owner's Manual page 67

Installation and operation
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

Figure 12.10 Remove Blower
8. Remove mounting plate from blower by removing the
four screws that hold the blower to the plate. Save the
gasket for use with the new blower. See Figure 12.11
and Figure 12.12.
Figure 12.11 Remove Mounting Plate
Figure 12.12 Remove Mounting Plate
9. Attach new blower to mounting plate by fastening the
four screws in the appropriate locations. The side of the
blower with the label on it must face toward the inside
of the appliance. This is the direction of the air fl ow.
See Figure 12.13.
Figure 12.13 Removed Mounting Plate
10. To install new blower back into appliance, reverse the
Figure 12.14 Blower Tab Toward Rear
Figure 12.15 Blower Tab Inserted into Slot on Blower Housing
Heat & Glo • RED60 • 2159-900 Rev. B • 12/09
removal procedure. Install blower assembly with the
tab toward the rear of the appliance. See Figure 12.14.
This tab must insert into slot on blower housing inside
the appliance as shown in Figure 12.15.
BLOWER TAB ON
MOUNTING PLATE
SLOT ON
BLOWER HOUSING
67