Operating Instructions; Maintenance - Heat & Glo RED60 Owner's Manual

Installation and operation
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

G. Operating Instructions
After installation of the power vent, follow the operation
instructions of the fi replace.
1. Turn the fi replace ON/OFF switch to "ON".
Note
: During periods of operation after turning the fi re-
place "ON", there will be a slight delay before the fi replace
ignites. This is due to the time necessary for the fan to
reach operating speed and to remove any gases from the
combustion chamber.
2. After turning the switch to the "ON" position, if the fi re-
place does not turn on, shut the switch to "OFF" and
inspect the power vent system for any debris that may
be obstructing the fan blade movement.
3. Turn the fi replace ON/OFF switch to "OFF" to turn off
the burner and the power vent.
H. Maintenance
CAUTION: Before performing any maintenance or repair
to the power vent assembly, make sure electrical power
is disconnected to the fi replace.
1. Vent System: Inspect all components and connections
annually. Replace, seal, or tighten pipe connections if
necessary.
2. Power Vent Cap: Inspect at least annually, to clear
away any debris blocking any part of the cap.
3. Motor: The fan motor bearings are sealed and no further
lubrication is necessary. To access the motor, vacuum
switch or pressure sense tube. Refer to Figure 7.19.
If the motor needs to be removed, take out the three screws
that attach the collar to the wall and the fi ve nuts holding
the motor down as shown in Figure 7.20
Figure 7.19 Motor and Electrical Access
Figure 7.20 Motor Service
Heat & Glo • RED60 • 2159-900 Rev. B • 12/09
REMOVE SCREWS (3)
REMOVE NUTS (5)
29