Safety Instructions ... 3 Introduction ... 3 Description of Air Filtration System How the PermaLife™ Air Purifier System Works ... 4 Air Purifier Components ... 4 Display and Control Keys ... 5 Operation Initial Operation ... 6 Remote Operation ... 8 Display Modes ...
Description of Air Filtration System ™ How the PermaLife Air Purifier System Works As the air is pulled into the purifier, the activated carbon pre-filter absorbs odors and catches large particles. Then, the air travels through the PermaLife™ Cleanable Filtration System where the smaller particles are collected.
Description of Air Filtration System Display and Control Keys The display and control keys allow for easy operation of the air purifier. IONIZER: Turns the ionizer on and off. ON/OFF: Turns the unit on and off. AUTO: Toggles between manual and auto modes.
Operation Initial Operation This section provides basic instructions on the use of your air purifier. After following these initial directions, please continue reading this booklet to learn how to operate the more advanced features of your air purifier. Basic Operation of the Air Purifier: 1.
Page 7
6. Plug the unit into a 120V electrical outlet and press the ON/OFF key. The air purifier will start with a low blower speed. 7. Use the UP/DOWN keys to adjust the blower speed to the desired level. If this is the first time you have used the air purifier or if the air purifier has been without power for over 12 hours, you will need to set the day and time.
Operation Remote Operation For your convenience, a remote control is provided with this air purifier. The remote may be used to turn the air purifier on or off and adjust the fan speed. Operating the Air Purifier with the remote: 1.
Display Modes Your air purifier has 3 display modes – Clock Display, Pre-Filter Display, and Filter Dis- play. When the unit is running, the display also provides additional information about the settings of the air purifier. The features for each mode and how to change modes is de- scribed below.
Operation Manual and Auto Operating Modes Your Hunter Air Purifier has two distinct operating modes – Manual and Auto. The Manual Mode allows you to override the control programs that have been set and to hold the settings until you adjust them. In Manual Mode, the automatic programs are not active. You select whether the unit is on or off and choose the blower speed.
Using the Ionizer Using the ionizer improves the quality of air in the room. Negative ions are released into the air and positively charged dust, smoke, and pollen particles are attracted to the negative ions. These particles settle out of the air and can be vacuumed up during normal cleaning. These particles are also more easily captured by the cleanable filter as they pass through the PermaLife™...
Operation Override of Auto Mode You can use two different methods to override Auto Mode. If you choose temporary over- ride, the air purifier will run at the temporary setting until the next scheduled program change. Permanent override will remain in effect until you return the unit to auto mode. When in Auto Mode, remote use acts as a temporary override.
Filter Run-Time Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Run-Time Counters that will monitor the number of hours your filters have been in use. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters.
Programming Setting Day and Time Setting the correct day and time allows the programs to work effectively and provides a clock for your reference. Although the instructions for setting the day and time are listed under Initial Operation, they are repeated below for your convenience. Adjusting Day and Time: (For example, Wednesday at 3:45 pm) 1.
NOTES: • The clock flashes when the time has not been set. • At any time while you are setting the Day/Time, you can press the PROGRAM key to toggle between AM/PM format and military time format. • To quickly exit the Day/Time setting mode, you can press the DISPLAY key or wait 15 seconds without pressing any keys.
Programming User Programming User programming allows you to set when the air purifier is on and what blower speed to use. You may define up to 4 programs for the weekdays and up to 4 programs for the week- end. Before starting the programming process, first you should determine what times and blower speeds will best fit your needs.
Page 17
To set or change the programs: 1. Press the PROGRAM key. Program 1 for weekdays will be shown with the hour position flashing to denote that you should set that value now. 2. Use the UP/DOWN keys to adjust the hour setting. Once set, press the PROGRAM key again.
Programming Reviewing Programs You may want to review the programs to confirm that the settings are still acceptable. The following steps show you how to review the programs. To review programs: 1. With the air purifier On, press and hold the PROGRAM key. After 2 seconds, the display will advance through the 4 programs for weekdays and then the 4 pro- grams for the weekend.
Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the air purifier. Since you will lose all of your programmed settings when the unit is reset, you should consult the Troubleshooting section (pg. 23) of the manual to re- solve the problem before using the Reset Feature.
Air Purifier Maintenance Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your air purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth.
6. Install the grill back onto the unit. First, line up the tabs on the bottom of the grill with the openings on the purifier base and then push the top of the grill forward until it is closed. 7. Plug in the air purifier. NOTE: This unit will not oper- ate unless the grill is in the correct position.
Problem 1. No Display 2. Display reads “door.” 3. Program number is flashing. 4. Programs are not running. 5. Time is not correct 6. Keypad does not work or display reads “Lock.” 7. Erratic Display or Operation. 8. Filter and/or Pre-filter Indicator is Flashing.
Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114, 1-888- 830-1326. For the name of our nearest authorized Hunter Fan Company Service Center, write to the Hunter Fan Company at the preceding address. You will be responsible for 41959-01 41959-01_3.30.06.pmd...
Page 25
The purchaser must present sales receipt or other document that establishes proof of purchase. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT, INDI- RECT, SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE AIR PURIFIER.
The Care-Free Programmable ® Fans Humidifier ™ Thermostat To learn more about Hunter Fan Company products, please see our Web page at: www.hunterfan.com ® HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS, TN 38114, USA 41959-01 Printed in China and Taiwan 41959-01_3.30.06.pmd...