DISCONNECT POWER CORD BEFOR E SERVICING
IM PORTANT - RECONNECT ALL GROUNDIN G DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control (Position 5) ......................... 7-(-11 ) F
Defrost Control .......................................... 60hrs @ 45 min
Overtemperature Thermostat .............................. 140-110 F
Defrost Thermistor ........................................................ 75 F
Electrical Rating: 115V AC 60 Hz ......................... 11.6 Amp
Maximum Current Leakage ................................... 0.75 mA
Maximum Ground Path Resistance .................. 0.14 Ohms
NO LOAD PERFORM ANCE
Control Position MID/MID
and Ambient of: ............................................... 70 F
Fresh Food, F ................................................ 34-40
Frozen Food, F .............................................. (-3) 3
Run Time, % ...................................................... <80 80-100
REFRIGERATION SYSTEM
Refrigerant Charge (R134a) ............................... 6.5 ounces
Compressor .................................................... 833 BTU/hr @
Minimum Compressor Capacity ......................... 22 inches
Minimum Equalized Pressure
@ 70 F ....................................................................... 40 PSIG
@ 90 F ....................................................................... 54 PSIG
Technical Data
IM PORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in
connection with its use.
INSTALLATION
Minimum clearance required for air circulation:
w/ no door openings
TOP ............................................................................................. 1"
SIDES ................................................................................... 0.125"
REAR ........................................................................................ 0.5"
AIR FLOW
90 F
34-40
(-3) 3
3000 RPM
– 5 –
EVAPORATOR