3-Way Valve Body
The valve body contains a cam, rotor and
magnet.
The rotor and cam are grooved to rotate with
the magnet.
The entire valve body has refrigerant fl owing
through it when the compressor is operating.
Use care not to damage the top of the valve
body when installing the coil on the valve.
A locating pin is used to correctly align the
valve body in the valve coil.
Failure to fully seat the valve in the coil or to
align it correctly with the pin can cause the
system to stop cooling.
Valve Body
Note: The 3-way valve comes only as a complete
assembly. Exploded view is for reference only.
Valve Rotation
The pulses of the valve coil cause the magnet
to rotate inside the valve body.
As the magnet rotates, it moves the cam at
the bottom of the valve.
Rotor
Cam
Magnet
The cam opens or covers the ports to the
capillary tubes.
– 28
Magnet
Stop Point
(Home Position)
Capillary Tube
Ports