DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding
wires, screws, straps, clips, nuts or washers
used to complete a path to ground are removed
for service, they must be returned to their
original position and properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control.......................................39°F
Electrical Rating: 120V AC 60Hz..............2.0 Amp
Maximum Current Leakage......................0.50 mA
Maximum Ground Path Resistance.............0.14 Ω
NO LOAD PERFORMANCE
Control Position and
Ambient Temperature of:
Fresh Food °F
Ice Compartment °F
Percent Running Time, %..........34-45
REFRIGERATION SYSTEM
Refrigerant Charge (R134a).................3.2 ounces
Compressor.........................................590 BTU/hr
Minimum Compressor Capacity
Vacuum...................................................21 inches
Minimum Equalized Pressure
@70°F.......................................................37 PSIG
@90°F.......................................................40 PSIG
Technical Data
Clearance must be provided for air circulation:
AT TOP.................................................................0
AT SIDES.............................................................0
AT REAR.................................................1.0 INCH
DOOR FRONT TO PROTRUDE FROM
CABINETS ...................................MIN. 1
70°F
90°F
33-45
33-45
(-5) -6
(-5) -6
50-65
– 6 –
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any
attempt to repair a major appliance may result
in personal injury and property damage. The
manufacturer or seller cannot be responsible for
the interpretation of this information, nor can it
assume any liability in connection with its use.
INSTALLATION
Evaporator
Capillary
Process Tube
Dryer
Compressor
3
/
INCH
4
Condenser