Invacare Jasmine JLS5 Installation And Operating Instructions Manual
Invacare Jasmine JLS5 Installation And Operating Instructions Manual

Invacare Jasmine JLS5 Installation And Operating Instructions Manual

Advertisement

Quick Links

Jasmine™ Scale JLS5
Assembly, Installation and Operating Instructions
NOTE: Check all parts for shipping damage. In case of shipping damage, DO NOT use. Contact carrier/dealer for 
further instruction.
To ensure the safe installation, operation and use of the Jasmine scale, these instructions MUST be followed:
DO NOT use this equipment without first reading and understanding these instructions. If you are
unable to understand the Warnings, Cautions, and Instructions, contact distributor before
attempting to use this equipment, otherwise, injury or damage may result.
The weight capacity is limited to the lowest rated capacity of any one of the components in use (i.e.,
Patient Lift, Sling or Scale). The patient's weight MUST NOT exceed the lowest rated capacity of any
component.
After ANY adjustments, repair or service and before use, make sure that all attaching component
parts are secure.
The patient and sling MUST be removed from the lift during these procedures. Otherwise, injury or
damage may result.
Invacare products are specifically designed and manufactured for use in conjunction with Invacare
accessories. Accessories designed by other manufacturers have not been tested by Invacare and are
not recommended for use with Invacare products.
JLS5 Kit Description
Description
Jasmine Scale
Washers
Swivel Bar Pin
Locknut
Screw
Spacers
Flat Washer
Remove the Swivel Bar or Cradle Attachment
NOTE: For this procedure, refer to FIGURE 1 on page 2.
1. Remove the side rubber caps (2 total, 1 per side).
NOTE: When the attaching hardware is removed, the pin, washer and o‐ring will become loose.
NOTE: Support the swivel bar or cradle attachment from underneath while removing the attaching hardware.
2. Remove the screw, washer, bushings, top rubber cap, nylon spacers, washer and nut that attach the 
swivel bar or cradle attachment to the boom. Retain all hardware.
For more information regarding Invacare products, parts, and services, please visit www.invacare.com
Part No 1152408
SAVE THESE INSTRUCTIONS
WARNING
ACCESSORIES WARNING
Quantity
1
2
1
1
1
2
1
JLS5 Scale Specifications
Weight Range:
Resolution:
Display:
Automatic Power Down:
Size:
Weight:
Power:
Battery Life:
Temperature Range:
1
Up to 500 lbs (226.7 Kg)
+/- 0.2 lbs (0.1 Kg)
Liquid Crystal Digital
Two minutes
5-3/4 L X 3-5/8 W X 4 H
.55 lbs
9-Volt Alkaline battery (included)
Approximately 1500 readings
50° To 104°F (10° To 40°C)
Jasmine™ Scale JLS5

Advertisement

Table of Contents
loading

Summary of Contents for Invacare Jasmine JLS5

  • Page 1 ACCESSORIES WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. JLS5 Kit Description...
  • Page 2 Install the Jasmine Scale NOTE: For this procedure, refer to FIGURE 1, Detail “A”. WARNING The Jasmine Scale MUST be installed in the orientation shown in FIGURE 1. Otherwise, injury may occur. NOTE: If the scale is installed incorrectly, the swivel bar or cradle attachment will not rotate freely, limiting patient  movement during transfer. 1. Align the holes in the top rubber cap, the holes in the Jasmine scale mounting bracket and the nylon  spacers with the holes in the boom mounting bracket. Refer to Detail “A” for hardware orientation. 2. Attach the Jasmine scale to the boom mounting bracket with a screw, washer, bearings, flat washer and  locknut. Refer to Detail “A” for hardware orientation. NOTE: Ensure the shaft of the screw passes through both sides of the boom mounting bracket. Install the Swivel Bar or Cradle Attachment NOTE: For this procedure, refer to FIGURE 1, Detail “B”.
  • Page 3: Operating The Scale

    The weight capacity is limited to the lowest rated capacity of any one of the components in use (e.g. Patient Lift, Sling or Scale). The patient's weight MUST NOT exceed the lowest rated capacity of any component. 1. Attach sling straps to the swivel bar. For proper attachment instructions refer to Attaching a Sling to the  Swivel Bar in the Jasmine Patient Lift Owner’s Manual, Invacare P/N 1150704. NOTE: For improved accuracy on the patient lift, attach all sling straps to the center hooks on both sides of the swivel  bar. However, patient comfort may require a different configuration of sling straps. 2.  Press the ON/OFF key.
  • Page 4 DO NOT operate key strokes with pointed objects (e.g. pencils, pens, fingernails, etc.) Otherwise damage to the key pad will result. NOTE: The display will indicate the last weight that was measured. The word ʺLOCKʺ will be seen in the display box. NOTE: The ZERO key is pressed in order to avoid capturing the weight of the sling and the hardware. If the ZERO key  is not pressed the weight of the sling and the weight of the hardware will be included in the weight displayed. NOT  ZERO‐ING OUT WILL GIVE A FALSE READING OF THE USERʹS TRUE WEIGHT. 3. Press the ZERO key. When the ZERO key is pushed the following will happen: A. The scale will reset to zero and the word ʺZEROʺ will appear in the display. B. The lock function will then be turned off and the word ʺLOCKʺ will disappear from the display. NOTE: The scale is now active and continually updating the weight display. 4. Place the patient in the sling. For patient placement instructions refer to Operation in the Jasmine Patient  Lift Owner’s Manual, Invacare P/N 1150704. 5. Activate the lift mechanism to raise the patient until they are completely supported by the lift. For patient  lifting instructions, refer to Lifting the Patient in the Jasmine Patient Lift Owner’s Manual, Invacare P/N  1150704. 6. Note the weight display. 7. When the weight display becomes stable press the LOCK button to lock the weight display. This will be  indicated by the word ʺLOCKʺ appearing in the display window.  NOTE: Should it be necessary to unlock the weight while the patient is still supported by the lift, the UNLOCK button  may be pressed. The weight will unlock and the word ʺLOCKʺ will disappear from the display window. The weight  value will then be updated. Once the weight becomes stable the weight can be locked again by pressing the LOCK button. NOTE: Stable being defined as the weight fluctuating ± two tenths of a pound. For example, a patient weighing one ...
  • Page 5: Replacing The Battery

    Door Swivel Bar pin Arrow (Swivel Bar not shown) FIGURE 3 Replacing the Battery Calibrate the Jasmine scale NOTE: For this procedure, refer to FIGURE 4. NOTE: The Jasmine Scale will be pre‐calibrated at the factory with the load cell. Should it be necessary to re‐calibrate  the scale, follow the instructions outlined below. 1. The patient and the sling MUST be removed from the scale to properly calibrate the Jasmine Scale. Refer  to Operation in the Jasmine Patient Lift Owner’s Manual, Invacare P/N 1150704, for further instructions. 2. For sling detachment instructions, refer to Lifting the Patient in the Jasmine Patient Lift Owner’s Manual,  Invacare P/N 1150704. 3. Turn the scale display power on by pressing the ON/OFF key. 4. Rotate the Swivel Bar until the back of the scale display is visible. 5. Insert the tip of a paper clip or similar tool into the small hole on the back of the scale display and press  the CAL button. NOTE: Once the CAL button is pressed, “CAL1” will be seen in the display window. 6. Press the UNITS key. The display reads CAL2. 7. Press the LOCK/UNLOCK key. The display reads UNLD.
  • Page 6: Troubleshooting

    SYMPTOM PROBABLE CAUSE SOLUTION Unit does NOT work properly. Battery failure. Check battery. Replace if necessary. Battery has been replaced and unit still does Contact Invacare. NOT work properly. Display Codes CALIBRATION REQUIRED ‐ Indicates improper stored calibration data, calibration is necessary. OCAP OVER CAPACITY ‐ Indicates a weight exceeding the capacity has been loaded on the scale. Jasmine™ Scale JLS5 Part No 1152408...
  • Page 7: Limited Warranty

    If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product.