Technical Specifications - Invacare Pegasus Operating Manual

Invacare pegasus
Hide thumbs Also See for Pegasus:
Table of Contents

Advertisement

12 Technical specifications

Permissible operating and storage conditions
Temperature range for operation
according to ISO 7176-9:
Temperature range for storage
according to ISO 7176-9:
Electrical system
Motor
Batteries
Main fuse
Charging dev ice
Output current
Output voltage
Input voltage
Operating temperature
(surroundings)
Storage temperature
Tires
Tire type
Tire pressure
 -25° ... +50 °C
 -40° ... +65 °C
 6 km/h: S1: 240 W, Max
 10 km/h: S1: 240 W, Max
 12 km/h: S1: 250 W, Max
 2 x 12V / 40 Ah (C20) Gel
 2 x 12V / 50 Ah (C20) AGM
 70 A
 8A 
 24V nominal (12 cells)
 200 – 250V nominal
 -25° ... +50°C
 -40° ... +65°C
 4.10 / 3.50 - 5 pneumatic
 2.8 bar
500 W
peak
600 W
peak
1200 W
peak
65