BGD42CF ACCESSING THE BLOWER

1. Remove the main door using the instructions on Pg #33.
2. Carefully remove the logs.
3. Remove the grate by lifting it off of the two securing pins.
4. Remove the 6 screws illustrated in Fig. 99 and lift out
the log support. Be careful not to lose the spacers for the
screws indicated.
FIGURE 108
FIGURE 108
5. Remove the 7 perimeter screws as illustrated in Fig. 100
and lift out the burner base. (The gas line
fl ex-connector should provide suffi cent movement to permit
shifting the burner assembly to the side)
FIGURE 109
FIGURE 109

INSTALLING THE BLOWER

FIGURE 110
Canada or the ANSI/NFPA 70
United States
If the fi replace was not
previously equipped
with a blower: route a
grounded 2-wire, 60hz
power cable to the re-
ceptacle / junction box.
At this point, it must be
strain relieved and in-
sulated.
W415-0566 / D / 08.30.07
SPACERS
INSTALLATION
TO BE DONE BY
A Q U A L I F I E D
INSTALLER and
must be electri-
cally connected
and grounded in
accordance with
local codes. In
the absence of
local codes, use
the current CSA
C22.1 C
ANADIAN
ELECTRICAL CODE
in the
NATIONAL ELECTRICAL CODE
FIGURE 111
The three slots on the blower mounting bracket allow ease
of adjustment when attaching the blower. For a quiet running
blower, do not allow the assembly to sit on the fi rebox base.
Slide the vibration reducing pad (A) into the clip (C) and up
against the threaded stud (B) at the other end. The blower
must be able to be positioned entirely onto the pad.
To ease installation of the blower, remove the hinge screen
and valve control door (lower louvres) from the base of the
fi replace.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower does
not touch the fi replace base or the fi rebox.
FIGURE 112
FIGURE 112
B B
A A
Attach the connectors from
the black and white wires
to the thermodisc and se-
cure the thermodisc brack-
et to the securing stud at
the bottom left of the unit
using a lock washer and
wing nut. Ensure that the
thermodisc touches the
fi rebox wall.
Attach the connectors from
the black and red wires to
the blower.
Attach and secure the variable speed switch using the
nut provided. Plug the harness cord into the receptacle.
Note: To improve access to the var-
iable speed control, we recommend
bending the mounting bracket for-
ward by approximately 10°.
The wire harness provided in this
kit is a universal harness. When
installed, ensure that any excess
wire is contained, preventing it
from making contact with mov-
in
ing or hot objects.
Because the blower is thermally
activated, when turned on, it will automatically start
approximately 10 minutes after lighting the fi replace
and will run for approximately 30-45 minutes after the
fi replace has been turned off. Use of the fan increases
the output of heat.
Drywall dust will penetrate into the blower bearings, caus-
ing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or
its compartment. Any damage resulting from this condi-
tion is not covered by the warranty policy.
FIGURE 113
FIGURE 113
FIGURE 114
FIGURE 115
C
C