Place the stove on a noncombustible floor or on a floor protec-
tor that extends a minimum of 6 inches (152mm) to the front,
(measured from the glass) 6 inches (152mm) to the sides and
1 inch to the rear of the hopper. It is also recommended that
floor protection be installed under any horizontal venting and
extending 2 inches beyond the vent measurement. Material
used for floor protection must have a k-factor of 2.24 or lower.
Example: 1" thickness of Durock® is rated at 1.92 k per inch,
which would meet the requirement.
Place the stove away from combustible walls at least as far
as shown in Figures 3,4 and 5. Note the difference in side wall
clearance with and without side shields.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that
the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter. (The
draft meter must have a minimum range of 0 to -0.5 Inches
Water Column.) Record the first reading. Connect flue pipe
to stove and be sure all doors and windows in the home are
closed. Record the second draft reading_______. If the second
reading is more than .05" lower than the first reading, check for
possible restrictions in the venting configuration or the need
for outside air (see page 9). For more information on the draft
test procedure, refer to Page 21.
Mobile home installation
When installing this unit in a mobile home, several require-
ments must be followed:
1. The unit must be bolted to the floor. This can be done with
1/4" lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page
9.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.
cautiOn: this appliance must be vented to the outside.
Due to high temperatures, the stove should be placed out of
traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns to
skin and/or clothing.
Young children should be carefully supervised when they are
in the same room as the stove.
Clothing and other flammable materials should not be placed
on or near this unit.
warning
the Structural integritY OF the
ManuFactured hOMe FlOOr, wall,
and ceiling/rOOF MuSt be Maintained.
dO nOt inStall in SleePing rOOM.
installation
9" With or Without Side Shields
Floor Protection must meet a minimum 2.24k value
or lower. (In "k", the lower the value, the better the
protection.) Floor Protector minimum: 32½" wide
x 33" deep.
9"
Fig. 3
10"
Fig. 4
2"
16"
Fig. 5
32½" minimum
6"
Fig. 6
P43 Pellet Stove
9"
1"
6"
(152mm)
6"- 152mm
(measured from
glass)