All installations and services must be performed by qualified service personnel.
Table 2: Burner Specifications and High and Low Fire Heating Performance
Oil Pump
Heating
Pressure
Mode
(PSIG)
High Fire
130
Low Fire
120
* Based on #2 fuel (domestic heating) oil having higher heating value of 140,000
BTU per gallon.
** Based on an assumed steady state, thermal efficiency of 80%.
For more specific burner information, consult the Model AFG Oil Burner
Instruction Manual or contact Thermo Products, LLC. P.O. Box 217, North
Judson, IN 46366. Phone no. 574-896-2133.
Oil Flowrate
Heat Input
@ Nozzle
Rate*
(GPH)
(BTUH)
0.75
105,000
0.6
85,000
Heat Output
Burner Model
Rate**
Number
(BTUH)
85,000
AFG-TP1501 AF35 BOSS
67,000
18
Air Tube
Nozzle
Combination
Type
Simplex, 80
deg., hollow
cone