Automatic Features - American Energy Systems T-40 AC Owner's Installation And Operation Manual

Pellet fuel burning heater
Table of Contents

Advertisement

A.
THERMOSTAT OPTION:
When using a thermostat, set the stove to one of the medium or higher settings. The
stove will burn at the rate selected on demand by the thermostat (medium to high).
When the room temperature drops below the thermostat setting, the thermostat switch
will close, allowing the stove to operate at the medium or higher settings. When the
room temperature matches the thermostat setting, the thermostat switch will open,
allowing the stove to operate at the low setting.
B.
THERMOSTAT EQUIPMENT REQUIRED (optional): A low voltage millivolt
thermostat that will automatically switch between settings previously selected.
Type CL2 thermostat wire-20 AWG, 2 conductors.
C.
STOVE PRESSURE SENSOR:
A blocked flue, a down draft, open door, or failure to clean the 3" exhaust in the stove
will cause the pressure switch to shut off the fuel feed. To resume operation, it is
necessary to locate the cause and correct it. Restart the stove following the
instructions in this manual.
D.
HIGH TEMP THERMODISK:
If the stove overheats, it will shut itself down safely. The stove may not be restarted
until it has cooled and the reset button is depressed. (See page 15)
E.
SELF-IGNITER:
Automatically ignites the pellets within 3-5 minutes, without the use of fire starter.
The igniter will continue to run for approximately 10 minutes until a fire is
established.
F.
PROOF OF FIRE THERMODISK:
If the temperature required by the PROOF OF FIRE thermodisk is not high enough
within the 10 minute cycle, the auger will stop feeding pellets.
G.
COOL DOWN SENSOR:
After the power switch has been moved to the "OFF" position, the blowers will
continue to run for approximately 15 minutes. The cool down sensor will allow the
stove to cool down and then automatically shut itself off. If the hopper runs out of
pellets and the stove cools off, the auger will stop feeding. However, the blowers will
continue to run until the power switch has been moved to the "OFF" position.

AUTOMATIC FEATURES

(2)