American Energy Systems T-40 AC Owner's Installation And Operation Manual

Pellet fuel burning heater

Advertisement

AMERICAN ENERGY SYSTEMS, INC.
OWNER'S INSTALLATION AND OPERATION MANUAL
FOR PELLET FUEL BURNING HEATER
Save these instructions
MODEL T-40 AC
SAFETY NOTICE
Please read this entire manual before you install and use your new stove. For your safety,
follow the installation directions. If your stove is not properly installed a house fire may
result. Contact your local building or fire officials about restrictions, installation
inspection and requirements in your area. Failure to follow instructions may result in
property damage, bodily injury or death.
.
American Energy Systems, Inc
A F A M I L Y O F H E A R T H P R O D U C T S
w w w . h e a r t h d i r e c t . c o m
150 MICHIGAN STREET SE
HUTCHINSON MN 55350
(320) 587-6565 FAX (320) 587-8872

Advertisement

Table of Contents
loading

Summary of Contents for American Energy Systems T-40 AC

  • Page 1 AMERICAN ENERGY SYSTEMS, INC. OWNER’S INSTALLATION AND OPERATION MANUAL FOR PELLET FUEL BURNING HEATER Save these instructions MODEL T-40 AC SAFETY NOTICE Please read this entire manual before you install and use your new stove. For your safety, follow the installation directions. If your stove is not properly installed a house fire may result.
  • Page 2: Table Of Contents

    SECTION PAGE Introduction……………………………………………………… Automatic Features……………………………………………… Safety Warnings…………………………………………………. 3, 4 Installation Precautions………………………………………….. Mobile Home Requirements…………………………………….. Clearances……………………………………………………….. Vent Termination Instructions…………………………………… Horizontal Installation…………………………………………… Vertical Installation………………………………………………. Control Panel/Thermostat Hook-up………………………………. Operating Instructions……………………………………………... 12, 13 Cleaning Instructions……………………………………………… 14, 15, 16, 17 Wiring Diagram……………………………………………………. Replacement Parts List…………………………………………….. Warranty…………………………………………………………….
  • Page 3: Automatic Features

    AUTOMATIC FEATURES THERMOSTAT OPTION: When using a thermostat, set the stove to one of the medium or higher settings. The stove will burn at the rate selected on demand by the thermostat (medium to high). When the room temperature drops below the thermostat setting, the thermostat switch will close, allowing the stove to operate at the medium or higher settings.
  • Page 4: Safety Warnings

    SAFETY WARNINGS If this stove is not properly installed, operated and maintained, a serious house fire may result. Always follow the recommended clearances to combustibles for this stove and the stove chimney. This appliance is designed specifically for the use of palletized wood. Never place wood, paper, furniture, drapes or other combustibles near the stove.
  • Page 5 SAFETY WARNINGS… CONTINUED FIRE EXTINGUISHER: Every home should have at least one fire extinguisher. An approved “class a-b-c” extinguisher should be mounted on the wall near an exit and close to the appliance, but not so close that accessibility to the extinguisher could be blocked by a fire. Your local fire department can advise you concerning the most appropriate location.
  • Page 6: Installation Precautions

    CAUTION: Do not install this appliance in any manner other than as described in this manual. If you have any questions about properly venting or installing your Reliant pellet stove, please contact your dealer or American Energy Systems, Inc. for information. NOTE: THIS STOVE MUST BE BURN TESTED OUTSIDE IN A WELL VENTILATED AREA FOR AT LEAST ONE HOUR.
  • Page 7: Mobile Home Requirements

    MOBILE HOME REQUIREMENTS SPECIAL MOBILE HOME REQUIREMENTS: WARNING: DO NOT INSTALL IN A SLEEPING ROOM. An outside air source must be connected to the stove and can be brought in through the sidewall or vented crawl space. Flexible or rigid pipe should be used and will connect to the adaptor on the back of the stoves.
  • Page 8: Clearances

    CLEARANCES CONVENTIONAL CLEARANCES A…SIDEWALL 9 In. (229 mm) B…BACK WALL 3 In. (75 mm)……(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3” CLEARANCE FROM COMBUSTIBLES TO VENT PIPE). C…CORNER WALL 3 In (75 mm)…….(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3” CLEARNACE FROM COMBUSTIBLES TO VENT PIPE). D…VENT PIPE TO WALL 3 In (75 mm)……..(MAINTAIN 3”...
  • Page 9: Vent Termination Instructions

    VENT TERMINATION INSTRUCTIONS NOTE: The following are general instructions for installing this appliance. THE VENT PIPE MANUFACTURER’S INSTRUCTIONS SHOULD BE FOLLOWED FOR THE VENT PIPE BEING USED. USE ONLY 3 INCH LISTED TYPE PL PELLET VENT PIPE. WARNING: Shut off all electrical power to the wall or room where the appliance is going to be installed before cutting any holes.
  • Page 10: Horizontal Installation

    HORIZONTAL INSTALLATION EXHAUST VENT TERMINATION SHALL BE AS FOLLOWS: A MINIMUM OF 4 FEET/122Omm BELOW, BESIDE AND 1 FOOT ABOVE ANY DOOR OR WINDOW THAT OPENS, OR ANY OPENING INTO A BUILDING. A MINIMUM OF 2 FEET/610mm FROM ANY ADJACENT BUILDING OR OVERHANG. A MINIMUM OF 7 FEET/2130mm ABOVE GRADE, WHEN LOCATED ADJACENT TO PUBLIC WALKWAYS.
  • Page 11: Vertical Installation

    VERTICAL INSTALLATION GUIDELINES ON CONNECTING TO AN EXISTING FACTORY-BUILT CHIMNEY: Inspect the chimney for the presence of creosote, soot or other combustible deposits, and blockage or obstructions. Thoroughly clean the chimney and remove any obstructions. Thoroughly inspect the chimney for soundness, proper clearances and presence of all necessary parts, including a chimney cap, prior to making the connection.
  • Page 12 USER DISPLAY DISCRIPTION USER CONTROL DEFINITION 1. (ON/OFF) ALLOWS USER TO TURN SYSTEM ON OR OFF WHEN CONTROL IS OPERATING IN MANUAL MODE ON/OFF LED WILL BLINK 1Hz DURING IGNITION & WHEN T-STAT OPEN/NOT CALLING FOR HEAT. 2. AUGER BUTTON ALLOWS AUGER MANUAL FEED & DISPLAYS LED FOR ON TIME OF AUGER MOTOR.
  • Page 13: Operating Instructions

    OPERATION INSTRUCTIONS…continued PROPER FUEL This stove is designed and approved to burn pelletized wood fuel only. Do not use any other type of fuel. Factory approved pellets are those ¼” or 5/16” in diameter and not over 1” in total length.
  • Page 14: Cleaning Instructions

    CLEANING INSTRUCTIONS NOTE: BE SURE THE STOVE IS TURNED OFF, THE POWER CORD IS UNPLUGGED, AND THE UNIT IS COLD BEFORE CLEANING OR SERVICING. RECOMMENDED CLEANING PERIODS: The heat exchange tubes in the stove should be cleaned weekly. The fire box should be cleaned every 7 to 10 days. The interior ash chambers should be inspected and cleaned as needed.
  • Page 15 CLEANING INSTRUCTIONS…continued WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING OR SERVICING THIS UNIT. THE STOVE MUST BE TURNED OFF AND COOLED BEFORE USING THE RAKE HANDLE. ASH RAKE HANDLE II. HEAT EXCHANGER: This stove is designed with a built-in heat exchange tube Rake.
  • Page 16 CLEANING INSTRUCTIONS…continued WARNING: BE SURE THE STOVE IS TURNED OFF AND THE UNIT IS COLD BEFORE CLEANING OR SERVICING. DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER CORD BEFORE SERVICING THIS UNIT. CAUTION: MOVING PARTS MAY CAUSE INJURY. DO NOT OPERATE UNIT WITH THE SIDE PANELS REMOVED.
  • Page 17 CLEANING INSTRUCTIONS…continued WARNING: DISCONNECT POWER CORD BEFORE CLEANING OR SERVICING. NOTE: CLEANING INTERVALS MAY VARY GREATLY WITH DIFFERENT BRANDS OF FUEL DUE TO THE ASH CONTENT, MOISTURE, AND MATERIAL COMPOSITION OF DIFFERENT FUELS. INSPECT AND CLEAN EXHAUST SYSTEM FREQUENTLY DAILY WEEKLY MONTHLY ANNUALLY FIREPOT...
  • Page 18: Wiring Diagram

    WIRING DIAGRAM WARNING: DISCONNECT POWER CORD BEFORE SERVICING THIS UNIT: OPTIONAL SOLAR PANEL CONNECTIONS WARNING: Use a 3 AMP, 50 volt diode on the “+” Positive lead between the solar panel and battery as shown in the diagram below. (18)
  • Page 19: Replacement Parts List

    This warranty is null and void unless the original purchaser fully completes the warranty card and the card is returned to the manufacturer, American Energy Systems, Inc. within 30 days after the date of purchase. This warranty is not assignable and is only extended to the original purchaser.

Table of Contents