D.h.w. flow switch, filter and flow limiter
14.6
Flow limiter
The Activ A 25C model is factory fitted with a 10 litres/
min. flow limiter.
The Activ A 30C. model is factory fitted with a 12 litres/
min. flow limiter.
The Activ A 35C. model is factory fitted with a 14 litres/
min. flow limiter.
The following sizes are available:
If the flow rate of the d.h.w. circuit is still too high, it is
possible to limit it by replacing the flow limiter. The fol-
lowing sizes are available:
Nominal flow rate (litres/min)
10
12
14
34
To install the flow limiter:
1
2
Colour
Fig. 14.4
Blue
3
Red
4
Pink
Remove the flow switch group as explained in the
section 14.5.
Separate the flow switch plug 1 from the body 4
levering with a screwdriver one of the two hooks.
Insert the flow limiter 3 as shown in Fig. 14.3
Reassemble the group following the above se-
quence in reverse order.
1
4