HP B6960-96035 Concepts Manual page 304

Hp projector user manual
Table of Contents

Advertisement

Department
* One HP StorageWorks DAT24 autoloader is currently used to locally back up the 12 GB
of data. The other HP StorageWorks DAT24 autoloader is used to back up the IDB and
configuration files. The rest of the data in this department is backed up remotely to the HP
StorageWorks DLT 41 15 library.
The remaining 4 HP StorageWorks DAT24 autoloaders are used in a separate R&D
system, which is not of our configuration.
The software components proposed for the Enterprise Backup solution include HP
Data Protector A.06.10.
Proposed solution in detail
The following is a detailed account of the proposed solution:
Cell Configuration
All clients and servers should be configured in a single Data Protector cell. The
Data Protector Cell Manager can run on the Windows 2000 Server of the English
Department.
All systems in the cell should be on the same LAN for maximum performance.
The Cell Manager should also be the Installation Server for Windows. Use the
HP-UX backup server of the Admin Department as the Installation Server for UNIX.
The HP StorageWorks DLT 41 15w Library should be connected to the Cell
Manager as well as one HP StorageWorks DAT24 autoloader for backing up
the IDB and configuration files. The Windows 2000 client, which accounts for
approximately a third of the data in the English Department (12 GB) should be
backed up locally to an HP StorageWorks DAT24 autoloader.
The proposed backup environment is as depicted in
304
Backup scenarios
Current Data
Projected Data
(In 5 Years)
Devices
Figure 92
on page 305: