Table 2. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
22003003
Gigabit Ethernet adapter failure.
25A00001
Level 2 (L2) cache controller failure.
25A10001
L2 cache static random-access
memory (SRAM) failure.
25A80xxx
Nonvolatile random-access memory
(NVRAM) problems.
25A8000
Initialization failed; the device failed
the test.
25A80100
The NVRAM data validation check
failed.
25A80201
Unable to expand target partition
while saving configuration variable.
25A80202
Unable to expand target partition
while writing BladeCenter
management-module event log entry.
25A80203
Unable to expand target partition
while writing VPD data.
25A80210
Setenv/$Setenv parameter error;
name contains a null character.
25A80211
Setenv/$Setenv parameter error;
value contains a null character.
25A80999
NVRAMRC script evaluation error;
stack unbalanced on completion.
86
BladeCenter JS20 Type 8842: Installation and User's Guide
Suggested action
If there is no adapter in the PCI slot in the blade server,
replace the system board. Contact a service support
representative for assistance.
If there is an adapter in the PCI slot in the blade server,
perform the following steps:
1. Turn off the blade server.
2. Remove the adapter; then, turn on the blade server.
3. If the problem no longer exists, replace the adapter
that you removed.
If the problem remains, replace the system. Contact a
service support representative for assistance.
Replace the system board. Contact a service support
representative for assistance.
Replace the system board. Contact a service support
representative for assistance.
NVRAM errors are caused by low-battery voltage or
power outages that occur during normal system usage.
Except for firmware error code 2580000, these error
codes are warnings that the NVRAM data content had to
be reestablished, and do not require any component
replacement, unless the problem remains. When one of
these error occurs, any system customization (for
example, the startup device sequence) has been lost.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
1. Turn off the blade server; then, turn it on.
2. Retry the operation before replacing any system
component.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
If the problem remains, replace the system board. Contact
a service support representative for assistance.
This is a firmware debug environment error. No action is
required. No component replacement is required.
If the problem remains, have the blade server serviced.