Chimney Requirements

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
IN CANADA: This appliance must be connected to a factory-built chimney conforming to CAN/ULC-
S629, Standard for 650ºC Factory-Built Chimneys.
UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap.
Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.
Chimney must be fastened to each adjoining section.
Follow the chimney manufacturer's clearances and requirements.
Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling.
No more than 180
the entire system (connector and chimney).
NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is
adversely affected. Additional chimney height may be required to boost draft.
(See the section "Chimney Termination
Requirements" for more details)
Factory Built Chimney Sections
Floor Penetration Equipment
(Attic Radiation Shield with Chimney Support)
Reduced Clearance Chimney
Connector Sections
Floor
Protection
Drafting
Performance
© Travis Industries
Stove Installation
o
o
of elbows (two 90
Chimney Cap
}
}
This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries cannot be
responsible for external forces leading to less than optimal performance.
(for qualified installers only)
o
elbows, or two 45
and one 90
}
Roof Penetration Equipment (Roof
Radiation Shield, Flashing, Storm Collar)
Minimum Air Space to Combustibles
(See Chimney Manufacturer's
Instructions)
Standard residential installations with reduced
clearance connector may use the clearance determined by
the manufacturer of the connector for the connector to wall
clearance or the clearance listed in this manual.
Mobile home installations must use the the reduced
clearance connector clearances listed in this manual under
"Additional Requirements for Mobile Home Installations".
Stove Clearance
(as outlined in this manual)
100-01275
o
elbow, etc.) may be used for
Minimum System 15' (4.57M)
Maximum System 33' (10.05M)
Figure 4