Clearances To Combustibles As A Built-In, Ul And Ulc - Quadra-Fire CASTILEI-MBK Owner's Manual Installation And Operation

Quadra-fire castile pellet insert
Hide thumbs Also See for CASTILEI-MBK:
Table of Contents

Advertisement

Castile Pellet Insert
B. Clearance To Combustibles, UL and ULC
C
Figure 10.1
A
Top of Hopper
B
Side of Hopper
C
Back of Hopper
D
Vent Pipe to Combustible
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Outside Air
Combustible
305mm
Mantel
Figure 10.2
Page 10
A
0 in. Clearance To Exposed Section And Face Trim
Must be installed in a non-tapered enclosure.
Top Vent:
51mm
Rear Vent:
64mm
Back of Hopper:
102mm
Vent Pipe to
Combustibles:
76mm
NOTE:
All Clearances are Minimum Clearances
AS A BUILT-IN
C
B
Top Vent
Rear Vent
Top or Rear Vent
Top or Rear Vent
Top or Rear Vent
152mm
Outside Air
7022-122D
D
B
Inches
Millimeters
2.0
51
2.5
64
2.0
51
4.0
102
3.0
76
WARNING
Fire Risk.
Comply with all minimum clear-
ances to combustibles as speci-
fi ed.
Failure to comply may cause
house fi re.
NOTE:
Illustrations refl ect typical installations
and are FOR DESIGN PURPOSES
ONLY.
Illustrations/diagrams are not drawn to
scale.
Actual installation may vary due to
individual design preference.
May 12, 2014