Appliance Set-Up
A. Leveling System
The leveling bolts are located at the rear of the appliance.
To access the bolts, remove the side access panels. Reach
in and turn the bolt to the desired height to level the appli-
ance. Shown in Figures 18.1 and 18.2.
Leveling Bolt on each Side
Figure 18.1
Page 18
2 inch diameter Flex Pipe
Figure 18.2
Air Intake Channel (Discard)
Hose Clamp
Collar
Assembly
B. Outside Air Kit Instructions
Parts Included in Kit: 1 piece of 2 inch x 3 ft. fl ex hose,
2 hose clamps, 1 collar assembly, 1 termination cap
assembly, 1 trim ring, fasteners and air intake channel
(discard).
Tools Needed: Phillips head screwdriver; wire cutters;
hole saw or jig saw.
1. Measure distance from fl oor to air vent opening in appli-
ance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
3. Use hose clamp to secure fl ex pipe to collar assembly.
4. Slide trim ring over fl ex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second
hose clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
Never draw outside combustion air from:
Wall, fl oor or ceiling cavity
Enclosed space such as an attic or garage
Leveling Bolt
Attach Termination
Cap to Exterior Wall
Trim Ring
Flex Hose
7022-122D
CAUTION
Termination
Cap Assembly
Hose Clamp
May 12, 2014