Outdoor Unit Installation - Heat Controller B-VCH12FC-1 Installation Manual

Version c inverterflex ductless mini-split heat pumps high wall and ceiling cassettes
Hide thumbs Also See for B-VCH12FC-1:
Table of Contents

Advertisement

Installation Manual

Outdoor Unit Installation

Outdoor installation precaution
• Install the outdoor unit on a rigid base to prevent
increasing noise level and vibration.
Outdoor unit installation
• Determine the air outlet direction where the
Outdoor installation precaution
discharged air is not blocked. If the installation
place is exposed to strong winds, ensure the unit
is lengthwise along the wall or provide a suitable
air baffle.
• If suspending the unit, follow the bracket manu-
facturer's instructions.
• Use a raised concrete pad or concrete blocks to
provide a solid, level surface. Securely anchor the
unit down with bolts.
• Be sure there are no obstacles which block radiat-
ing air.
• In a snowy area, install the outdoor unit on a raised
platform that is higher than drifting snow.
Anchoring outdoor unit
Anchor the outdoor unit with 5/16" (8mm) or 3/8"
(10mm) bolt and nut tightly and horizontally on a
concrete or rigid mount.
Outdoor unit dimensions
WxHxD in. (mm)
29.9 x 23.2 x 11.2 (760 x 590 x 285)
33.3 x 27.4 x 13.2 (845 x 695 x 335)
35.2 x 33.9 x 13.0 (895 x 860 x 330)
39.0 x 38.0 x 14.0 (990 x 965 x 355)
Install the outdoor unit on a rigid base to
prevent increasing noise level and vibration.
Determine the air outlet direction where the
discharged air is not blocked. In the case that
the installation place is exposed to strong wind
such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along the
wall or using a dust or shield plates.
Specially in windy area, install the unit to prev-
ent the admission of wind. If need suspending
installation, the installation bracket should
accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick,
concrete or the same intensity construction, or
actions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
Be sure there is no obstacle which block
radiating air.
Settlement of outdoor unit
A in. (mm)
Anchor the outdoor unit with
20.9 (530)
a bolt and nut ¦10 or ¦8 tightly
and horizontally on a concrete
22 (560)
or rigid mount.
23.2 (590)
Outdoor unit dimensi on
mm(L1x HxW1)
24.5 (623)
760x590x285
845x700x320
900x860x315
990x965x345
VMH SerieS
Mounting Dimensions
B in. (mm)
11.4 (290)
13.2 (335)
13.1 (333)
Mounting dimensions
14.4 (366)
L2(mm) W2(mm)
530
290
560
335
590
333
624
366
16
INSTALLATION INSTRUCTIONS
Fig.44
Fig. 45
23
Heat Controller, Inc.
Strong
wind
D
q
Fig.45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents