VMH Inverter Mini-Split
Outdoor Unit Installation
Outdoor installation precaution
• Install the outdoor unit on a rigid base to prevent
increasing noise level and vibration.
• Determine the air outlet direction where the
discharged air is not blocked. If the installation
place is exposed to strong winds, ensure the unit
is lengthwise along the wall or provide a suitable
air baffle.
• If suspending the unit, follow the bracket manu-
facturer's instructions.
• Use a raised concrete pad or concrete blocks to
provide a solid, level surface. Securely anchor
the unit down with bolts.
• Be sure there are no obstacles which block radi-
ating air.
• In a snowy area, install the outdoor unit on a
raised platform that is higher than drifting snow.
Anchoring outdoor unit
Anchor the outdoor unit with 5/16" (8mm) or 3/8"
(10mm) bolt and nut tightly and horizontally on a
concrete or rigid mount.
Model
(Btu/h)
9,000/12,000
29.9 x 23.2 x 11.2 (760 x 590 x 285)
18,000
33.3 x 27.4 x 13.2 (845 x 695 x 335)
24,000
35.2 x 33.9 x 13.0 (895 x 860 x 330)
Drain joint installation
Fit the seal into the drain elbow, then insert the drain
joint into the base pan hole of outdoor unit, rotate
90° to securely assemble them. Connecting the drain
joint with an extension drain hose (locally purchased)
is recommended.
INSTALLATION MANUAL
Outdoor unit dimensions
WxHxD in. (mm)
Mounting Dimensions
A in. (mm)
B in. (mm)
20.87 (530)
11.42 (290)
22.04 (560)
13.19 (335)
22.2 (564)
13.19 (335)
7
Heat Controller, Inc.
Fig. 14
Fig. 15
Fig. 16